OPEL communication items
During the test mode, OPEL communication line outputs the
following (At every 500msec, the output condition of the com-
munication line will be switched.)
[6] key
Press for less than 1 second : PANEL Open/close
number is displayed. (*1)
During PANEL Open/close number display, by pressing
for at least 2 seconds, PANEL Open/close numbers is
cleared.
(Display) PnCnt_XXXXXX
MAX 65535(times)
[FM]
ROM correction version display
key
(Display) SYS_ROM_R123
(Display) PAN_ROM_R123
When E2PROM is not installed : ROM_ERR_
When un-written : ROM_R – – –
When data is incompatible : ROM_R
∗ ∗ ∗
AUDIO data default value setting
key
(Display) AUDIO_INIT
Press for less than 1 second : CD mechanism error log display
key
During CD mechanism error log display; by pressing for
at least 2 seconds, all error log information is cleared.
(Display) I2C_
●●
(Display) ERR_1–
▲▲
, 2–
▲▲
, 3–
▲▲
∗
In “
●●
”, “OK” or ”NG” is displayed.
In “
▲▲
”, “– –” or an error code is displayed.
(*1) : 1 count is made when the panel opens to full or when a disc is
loaded.
●
Initializing AUDIO-related value setting
During STANDBY sourcing, by pressing [
] key for less than
1 second, AUDIO setting values are returned to the default
values.
●
Flash ROM check
1. In order to prevent the Flash ROM (4M) equipped models
to be installed with the Mask ROM (2M) panel, and to pre-
vent the Mask ROM (2M) equipped models to be installed
with the Flash ROM (4M) panels, with the STANDBY
sources during the test mode, the following display will be
made according to the system
µ
-com and panel combina-
tion.
• Flash ROM (4M) equipped model and Flash ROM (4M) panel
All lights turned on – – – OK!
• Mask ROM (2M) equipped model and Mask ROM (2M) panel
All lights turned on – – – OK!
• Flash ROM (4M) equipped model and Mask ROM (2M) panel
“M4P2” – – – NG!
• Mask ROM (2M) equipped model and Flash ROM (4M) panel
“M2P4” – – – NG!
TEST MODE
CE
DATA
CLK
500msec
500msec
500msec
●
G sensor display items
When source is STANDBY, by short-pressing [ATT] key, the
display is switched to analogy meter display, in which vertical
G and horizontal G are displayed.
●
Special display when all lights are on
When all lights are on with the STANDBY source, the follow-
ing displays are made when the keys shown below are pressed.
[1] key
Version display
(Display) C-408WK_SYS_1. 23
(Display) _________PAN_1. 11
(Display) ________MEM_3. 21
[2] key
Serial number display (8 digits)
(Display) SNo_XXXXXXXX
[3] key
Press for less than 1 second : Power ON time is displayed.
During Power On time display, by pressing for at least 2
seconds, the Power ON time is cleared.
MAX 65535 (hours)
Press for less than 1 second : CD operation time is displayed.
During CD operation time display, by pressing for at least
2 seconds, CD operation time is cleared.
MAX 65535 (hours)
Press for less than 1 second : CD EJECT number is displayed.
During CD EJECT number display, by pressing for at
least 2 seconds, CD EJECT number display is cleared.
(Display) EjeCnt_XXXXX
MAX 65535 (times)
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299