22
AO
AP
AQ
AR
AS
1
2
3
4
5
6
7
ED1(COMMON)
KDC-M6024/G/GY/Y (3/3)
KDC-MPG522, X569 (3/3)
EQ
4
6
5
2
1
SRC
AM
FM
Q3
IC1
: LC75808W
IC2
: PNA4S22M
Q2
: DTA114EUA
Q4
B30-1571-05
D19
:
D17,18
:
3
Q1,3-5
:
B30-1605-05
D1-14
:
B30-1564-05
D15,16
:
KEY
SW
MA3091-L
D15
D16
ILLUMINATION
2SC4081
D14
D13
D12
D6
D9
D3
D11
D5
D8
D2
D10
D4
D7
D1
AUTO
CLK
S5
S4
S3
S2
S1
S6
S14
S7
S15
S16
S8
S17
S18
S10
S19
S20
S12
S22
S21
S13
S1
1
S
9
GND LINE
B LINE
Q5
D18
D17
SW
DIMMER
CONTROL
C8
C7
C4
C5
C6
C2
C1
C3
SEG1
1
59
SEG5
65
SEG1
SEG2
SEG3
SEG4
68
69
67
66
SEG6
SEG7
SEG8
SSEG9
SEG10
62
64
63
60
61
SEG12
SEG13
SEG14
SEG15
SEG16
SEG17
58
57
56
55
54
53
SEG18
SEG19
SEG20
SEG21
SEG22
SEG23
52
50
51
49
48
47
SEG24
SEG25
SEG26
SEG27
SEG28
SEG29
46
44
45
42
43
41
SEG34
SEG35
SEG30
SEG31
SEG32
SEG33
40
38
39
35
36
37
28
SEG42
SEG39
SEG40
SEG41
SEG36
SEG37
SEG38
32
33
34
29
30
31
SEG43
SEG44
SEG45
25
26
27
SEG56
6
3
1
2
4
5
SEG53
SEG55
SEG54
SEG52
SEG51
9
7
8
SEG59
SEG57
SEG58
SEG48
13
10
11
12
SEG60B
SEG46
SEG47
14
16
15
18
17
19
SEG60A
SEG49
SEG50
COM7
COM8
COM6
21
20
22
24
23
COM4
COM5
COM3
COM1
COM2
330
R20
KS5
KS4
KS3
KI1
KI2
KI3
KI4
2.2K
R16
KI5
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
27
26
20
21
22
23
24
25
S57
S56
S55
S54
S53
S52
S51
S45
S44
S43
S42
S41
S40
S39
S38
S37
S36
S35
S34
S33
S32
S31
S30
S29
S28
S27
S26
S20
S21
S22
S23
S24
S25
S20
S21
S22
S23
S38
S34
S32
S31
S33
S36
S35
S37
S46
S42
S40
S39
S41
S44
S43
S45
S47
S50
S30
S29
S57
S56
S55
S54
S53
S52
S51
2.2K
R18
S49
S48
S25
S24
S50
S46
S47
S48
S49
28
29
30
31
32
S28
S27
S26
330
R22
330
R23
330
R24
360
84
83
2.2K
R19
2.2K
R17
KDC-X569
MODEL NAME
KDC-M6024G
UNIT No.
X16-2222-70
0.01
0.01
R25
360
KDC-MP522
X16-2020-10
KDC-6023
Q3,4
C8
C9
TP27
TP26
TP25
TP24
TP23
TP22
TP21
TP20
TP19
TP18
TP28
TP29
TP30
TP31
TP33
TP32
R21
KDC-M6024GY
K
E
M
9
R28
4.7K
R27
4.7K
0.01
C13
0.01
C12
270
R26
E2
KDC-M6024Y
KDC-6024Y
KDC-6024
KDC-M6024
CAUTION : For continued safety, replace safety critical components
only with manufacturer's recommended parts (refer to parts list).
Indicates safety critical components. To reduce the risk of electric
shock, leakage-current or resistance measurements shall be carried
out (exposed parts are acceptably insulated from the supply circuit)
before the appliance is returned to the customer.
• DC voltages are as measured with a high impedance voltmeter.
Values may vary slightly due to variations between individual
instruments or/and units.
!
X16-2020-10/2222-70 (2/2)
KDC-M6024/G/GY/Y
KDC-MP522,X569