4.12. Tilt Mecha Position Adjust screen
Adjust the panel mechanism position from this screen.
The Tilt Mecha Position Adjust screen is displayed in Figure
4.12.
Cancel
Return
Tilt Mecha Adjust
Tilt Mecha Adjust
E
Mecha Adjust OK/NG
Mecha Adjust
Figure 4.12 Tilt Mecha Position Adjust screen
Key Speci
fi
cation
Mecha Adjust : Start adjusting the mechanism position.
Cancel
: Transfer to Test Mode Main screen.
Return
: Transfer to Test Mode Main screen.
If the “Mecha Adjust NG” is displayed (i.e., in case of failure
in writing data in the nonvolatile memory), re-enter in the
Test Mode again to start over the adjustment.
The “NG” is displayed when the status is in any one of the
following conditions: (When the “NG” is displayed, no data
is written in the nonvolatile memory.)
Failure in writing data in nonvolatile memory
When the voltage acquired is 0.177V or higher in the
Open condition
When the voltage acquired is lower than 2.746V or it is
higher than 2.888V in the Close condition
Note:
In case of “NG”, check if the mechanism position
adjustment jig is properly installed or not, and then
transfer to the Test mode again to start over the ad-
justment.
4.13. Bluetooth Con
fi
rmation screen (only in Mid model)
Perform LOOPBAK test with the other Bluetooth device in
the line.
The Bluetooth Confirmation screen is displayed in Figure
4.13.
• Detect other Bluetooth devices in the line with [Search]
key (The detected devices are listed in the screen).
• Select one device that is used as a counterpart of the
LOOPBACK test from the device list displayed on the
screen. (The selected device is highlighted with the dif-
ferent color from others.)
• Start the LOOPBACK test when “Complete” is displayed
in the stats display area.
• After the completion of the LOOPBACK test, press [Clear]
key to initialize the flash memory and to set “0000” in
PIN Code. The “OK” indicates the completion of the test.
“NG” indicates that you have to enter in the Test mode
again to start over the test.
• After the completion of the initialization, [Device Name]
key is inactive and invalid. Return to the Test Mode Main
screen again if the re-adjustment is needed.
Return
Bluetooth
Search
Clear
OK / NG
Status displayed
Device Name1
Device Name2
Device Name3
Device Name4
Device Name5
▲
▼
Figure 4.13 Bluetooth Con
fi
rmation screen
Key Speci
fi
cation
Search
: Search Bluetooth device.
▲
▼
:
Use this key to scroll the device list when
there are more than 5 devices found.
Device Name : Connect to the selected device (and then
start the LOOPBACK test after the com-
pletion of the connection).
Clear
:
Initialize the flash memory and to set
“0000” in PIN Code.
Return
: Transfer to the Test Mode Main screen.
Status display speci
fi
cation
Searching :
Indicate the status in which Bluetooth de-
vices are being searched.
Complete :
Indicate the status that is ready to start
the LOOPBACK test after the completion
of the connection with the device.
Connect NG : If the connection with the device is failed,
select a device again and try to make the
connection with it.
4.14. Parrot Check screen (only in Mid model)
The Parrot check screen is displayed in Figure 4.14.
TEST MODE