37
TABLE FOR THE CHOICE OF THE INJECTORS
Cat:
II
2H3+
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION
(2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Triple-ring
7,00
Left Oven
7,40
Left Grill
5,00
Right Oven
4,40
Right Grill
4,00
BURNERS
Auxiliary (A)
1,00
0,30
27
50
-
adjustable
72 (X)
-
Semi-rapid (SR)
1,75
0,45
32
65
-
adjustable
97 (Z)
-
Rapid (R)
3,00
0,75
42
85
-
adjustable
115 (Y)
-
Triple-ring (TR)
3,50
1,50
65
95
-
adjustable
135 (T)
-
Left Oven
3,70
0,75
42
92
fully open* adjustable
140
5 *
Left Grill
2,50
-
-
80
fully open*
-
120
4 *
Right Oven
2,20
0,63
39
72
fully open* adjustable
110
4 *
Right Grill
2,00
-
-
70
fully open*
-
105
2 *
Nominal
Power
[kW]
Reduced
Power
[kW]
G 30 - 28-30 mbar
G 31 - 37 mbar
G 20
20 mbar
By-pass
[1/100 mm]
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
*
= Reference value
Ring opening
[mm]
Ring opening
[mm]
IE