6
Ford 6.7 Liter Engine
1)
Remove tube shown in picture (both ends)
2)
Attach DFS 910-18 adapter in place of
tube making sure that the intake and exhaust sides of
the adapter are on the correct side.
3)
Attach the DFS 910-5 to the DFS 910-18 and
connect the blue and black hoses to the DFS
910-5
4)
Start the engine and let it get to operating temp.
With the engine at operating temperature use
your scan tool to open the EGR.
5)
Making sure that the Atomizer Valve is closed
6)
Set the pressure on the induction side of the DFS 910 to 80lbs
7)
With the Engine still running open the air valve on the DFS 910-5 and turn the
Atomizer valve to the on position. When half (1 liter of the cleaner) is used turn
the Atomizer valve to off and switch the valve on the DFS 910-18to the Exhaust
side. Using your scan tool you can now close the EGR. Run the rest of the
cleaner out. Repeat step seven with the Rinse using half on the intake side and
the rest on the exhaust side.
DFS 910-18