background image

17

 

 

 

 

 

 
 Controller 

Number 

 Control 

Function 

 
 Decimal 

 

Hex

 

 

0  

  

00H  

 

Bank select MSB 

 1 

 01H 

 

 Modulation 

wheel/lever 

 2 

 02H 

 

 Breath 

controller 

 3 

 03H 

 

 Undefined 

 4 

 04H 

 

 Foot 

controller 

 5 

 05H 

 

 Portamento 

time 

 6 

 06H 

 

 Data 

entry 

MSB 

 7 

 07H 

 

 Main 

volume 

 8 

 08H 

 

 Balance 

 9 

 09H 

 

 Undefined 

 10 

 0AH 

 

 Pan 

 11 

 0BH 

 

 Expression 

controller 

 12-15 

 0C-0FH 

 Undefined 

 

16-19   

10-13H   

General purpose controllers (1-4) 

 20-31 

 14-1FH 

 Undefined 

 

32-63   

20-3FH  

LSB for controllers 0-31 

 

64 

 

40H  

 

Damper pedal (sustain) (Hold 1) 

 65 

 41H 

 

 Portamento 

 66 

 42H 

 

 Sostenuto 

 67 

 43H 

 

 Soft 

pedal 

 68 

 44H 

 

 Undefined 

 69 

 45H 

 

 Hold 

 70-79 

 46-4FH 

 Undefined 

 

80-83   

50-53H   

General purpose controllers (5-8) 

 84-90 

 54-5AH 

 Undefined 

 91 

 5BH 

 

 External 

effects 

depth 

 92 

 5CH 

 

 Tremolo 

depth 

 93 

 5DH 

 

 Chorus 

depth 

 94 

 5EH 

 

 Celeste 

(detune) 

depth 

 95 

 5FH 

 

 Phaser 

depth 

 96 

 60H 

 

 Data 

increment 

 97 

 61H 

 

 Data 

decrement 

 

98 

 

62H  

 

Non-registered parameter number LSB 

 

99 

 

63H  

 

Non-registered parameter number MSB 

 

100 

 

64H  

 

Registered parameter number LSB 

 

101 

 

65H  

 

Registered parameter number MSB 

 102-119 66-78H 

 

 Undefined 

   

120-127 

79-7FH  

Reserved for channel mode messages 

 

STANDARD MIDI CONTROLLER NUMBERS 

Summary of Contents for USB SOLO

Page 1: ...U U U US S S SB B B B S S S SO O O OL L L LO O O O USB Single channel MIDI CV converter Operating manual...

Page 2: ...nterference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television...

Page 3: ...g MIDI controllers Velocity mod wheel etc Note not all mono synths have such additional control inputs AUX2 digital aux out Use this to control switchable inputs Signal is either zero or 5V AUX3 clock...

Page 4: ...e displayed Minus values up to 127 or positive values up to 255 are used The display will automatically revert to parameter mode after approximately 10 seconds if neither inc or dec are pressed The va...

Page 5: ...the newest valid note played takes precedence The USB SOLO has a 5 note buffer memory so that trill effects can be achieved P 04 Pitchbend range default 2 Range 0 to 12 semitones The pitch bend range...

Page 6: ...at minimum can be set above maximum so that the controller works backwards Why would I want to do this The modulation amount at mod wheel maximum may be too great or too little P 11 LFO to CV reset va...

Page 7: ...d SCI ARP Oberheim The low level gate may be needed for synths that require a lower gate voltage such as the SH 101 S trig no pull up S 00 This would be used for most Moogs Korgs and some Yamaha synth...

Page 8: ...17 Sets which Controller will control the LFO depth applied to the AUX1 output The following can be selected Off oFF Pitch bend Pbd Velocity VEL Aftertouch AFt MIDI controllers 0 to 119 P 26 LFO to A...

Page 9: ...set for see below for divide ratios A divide ratio can be set so the LFO only re triggers every so many MIDI clock messages MIDI sends 24 clocks per quarter note So if divide is set to 1 there will be...

Page 10: ...ulse output for every 24 MIDI clocks 1 cpqn Note there are 24 MIDI clocks per quarter note Below is a table of values you can set the divide ratio to in order to obtain a clock pulse at various musica...

Page 11: ...with no adjustment necessary One intended use for Auxes 2 3 is to control the accent slide of our 5 socket kit for the TB 303 If you are not using a sequencer you will need some way of linking your MI...

Page 12: ...Parameters mode displays GPA decribed below INC only Displays the firmware revision number described below SEL DEC Powers up without USB from plugging cable in only displays NoU SEL INC Receive firmw...

Page 13: ...selected the USB SOLO will display the value it receives for the type of message currently selected Although pitchbend and after touch are not strictly controllers when Controller number Cn mode is s...

Page 14: ...ock problems on our website in the Information and FAQs section Clock Stop Start signal is available at the Aux 2 output if selected as the controller source Para 42 Clock with a rate of between 1 and...

Page 15: ...he synth it will not always be clear what type of CV and GATE signals are required to play the synth For instance the Korg MS20 requires an S TRIG signal but the input is labelled TRIG Another example...

Page 16: ...output into the external control input of the synth e g Filter input the cut off frequency can be controlled over MIDI The AUX output is not controlled by MIDI note numbers The converter allows you t...

Page 17: ...r pedal sustain Hold 1 65 41H Portamento 66 42H Sostenuto 67 43H Soft pedal 68 44H Undefined 69 45H Hold 2 70 79 46 4FH Undefined 80 83 50 53H General purpose controllers 5 8 84 90 54 5AH Undefined 91...

Page 18: ...h low 7 bits of parameter address 10 0uuuuuuu where uuuuuuu high 7 bits of data either 0 or 1 for usb solo 11 0hhhhhhh where hhhhhhh low 7 bits of data 12 0F7h end of exclusive The USB SOLO responds b...

Page 19: ...et value 0 127 25 Lfo speed 0 191 26 Lfo waveshape 0 8 7 27 Lfo MIDI sync 0 96 8 28 Lfo sync start point 0 255 29 Key on resets LFO wave 0 1 10 30 cont start 0 1 11 31 clock divide 0 24 9 32 Aux 2 con...

Page 20: ...applies to the European Union other European countries with separate collection systems The crossed out wheelie bin symbol affixed to this product indicates that it should not be disposed of with othe...

Reviews: