Maintenance

TDS Adjustment

*

Although the rejected water has high concentration of salts, it is absolutely clean and free of 

impurities like chlorine, dirt, sand, etc. which are present in raw water. This rejected water usually 

goes down the drain but if required, can be used for gardening purposes. It has high concentration 

of salts and minerals which accelerate plant growth. Rejected water can also be used for cleaning 

purposes, i.e. utensils cleaning, mopping, etc.

Recommended  Usage  of  Reject  Water

n

n

n

n

n

n

n

Switch  on  the  power  supply

Allow  the  storage  tank  to  fill  to  the  maximum  level**

Switch  off  the  power  supply

Open  the  drain  plug  present  at  the  bottom  of  the  storage  tank  and  drain  the  tank  to 

remove  residual  dust  particles  present  in  the  pipes  and  storage  tank

Plug  back  the  drain  plug

Switch on the power supply 

Purifier is ready to use

We  recommend  keeping  the  TDS  at  lowest  but  not  below  50mg/l. 

Starting  Up  the  Purifier

8

n

n

n

n

n

Storage  tank  must  be  drained  once  in  2 

Replace RO membrane once in a year

weeks. To do so, switch off the power supply. 

Replace UF membrane once in a year

Open the drain plug present at the bottom of 
the  storage  tank  and  drain  the  tank.  Plug 

In the event of not using purifier for a long time 

back the drain plug and switch on the power 

(while going for a holiday, tour etc.), make sure 

supply

that you disconnect the power supply, turn off 
the  raw  water  supply  and  drain  the  storage 

Replace sediment filter & activated carbon filter 

tank

once in a year. It is recommended to change 
FRT along with the filters

To  ensure  that  the  purifier  operates  at  its  BEST,  a  routine  maintenance  must  be  performed. The 
frequency of the maintenance will greatly depend upon the raw water quality and consumption of 
purified water.

The replacement time of consumables such as filters and membrane is dependent 
on the quality of raw water and water consumed.

* Tested  &  Certified  by TUV-SUD  South Asia  (P)  Ltd.
** Tested  or  certified  flushing  time  -  24hrs.

Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of raw 
water and water consumption. They are not covered under the warranty. However, if a filter chokes within six 
months and a membrane within a year, it will be cleaned/repaired/replaced free of cost. Changing the filters 
and system inspection is available on call. The treatment capacity of RO membrane will reduce with time  due  
to  clogging  of  pores  of  membranes.

“This reverse osmosis system contains a replaceable component critical to the efficiency of the system. 
Replacement of the reverse osmosis component should be with one of identical specifications as defined by 
the manufacturer, to ensure the same efficiency and contaminant reduction performance.”

The reverse osmosis system contains a replaceable treatment component critical for the effective reduction 
of  total  dissolved  solids  and  that  product  water  shall  be  tested  periodically  to  verify  that  the  system  is 
performing properly.

Replacement of spare parts are as under:-

-20010   SP Inline Sediment Filter 8”

-20009   SP Inline Carbon Filter 8”

-20001   SP RO Membrane Welded 10” Housing 

-20004   SP UF Membrane Welded 8”

-20018   SP FRT 550

n

n

Turning  the  screw  of  the  valve  clockwise 

results in a decreased mineral content.

Turning the screw of the valve anti-clockwise 

results in an increased mineral content.

The unique TDS Control System enables customers to retain the contents of natural minerals (TDS) in 

purified water, as per their requirement.

Summary of Contents for Pride Mineral Ro

Page 1: ...dia Call Toll Free 1800 100 1000 or Fixed line 91 120 4669666 E mail service kent co in Marketed by A 2 Sector 59 Noida U P 201 309 India Ph 91 120 3075075 E mail sales kent co in Website www kent co in KENT RO SYSTEMS LTD Manufactured by Khasra No 93 Village Bantakhedi Tehsil Roorkee District Haridwar Uttarakhand 247 668 India KENT RO SYSTEMS LTD April 2015 System Tested and Certified by WQA to N...

Page 2: ... performance of our products TM We are confident that your decision to own PRIDE MINERAL RO water purifier will go a long way in serving you with purer and mineral enriched drinking water thus keeping you and your family in good health We assure you that you will be satisfied with its trouble free performance and quality which comes without any compromise This manual is an effort towards familiari...

Page 3: ...age tank provides water on ABS construction for corrosion free life demand span RO and UF Membranes fused inside Suitable for Purification of Brackish membrane housing to prevent tampering Tap Water Municipal water Supply Items in the Box Tested Certified by TUV SUD South Asia P Ltd Purer Water Reduces Bacteria Cyst Reduces Dissolved Impurities KENT TECHNOLOGY A Breakthrough in Water Purification ...

Page 4: ...te The process ensures the reduction of particles as small as ions from a solution Reverse Osmosis uses a semi permeable membrane to reduce salts from potable brackish water In Reverse Osmosis water pressure applied to the concentrated side forces the process of osmosis into reverse Under enough pressure purer water is squeezed through the membrane from the concentrated side to the diluted side Sa...

Page 5: ...e tank is full The purifier does not allow any water The purifier does not start when inlet water rejection in absence of electricity when 2 tank is full supply pressure falls below 0 3 kg cm The purifier automatically restarts when TM KENT PRIDE Mineral RO is a convenient and easy to install wall mounting model Recommended Site Preparations Single Phase 100 250 V AC 50 60 Hz supply not more than ...

Page 6: ...be performed The frequency of the maintenance will greatly depend upon the raw water quality and consumption of purified water The replacement time of consumables such as filters and membrane is dependent on the quality of raw water and water consumed Tested Certified by TUV SUD South Asia P Ltd Tested or certified flushing time 24hrs Note Filters and membrane are consumables Their replacement tim...

Page 7: ...er it has not been evaluated for its ability to remove trivalent arsenic Trivalent arsenic is generally more difficult to remove from drinking water than pentavalent arsenic Trivalent arsenic can be converted to pentavalent arsenic in the presence of an effective oxidant such as free chlorine The arsenic in water containing detectable free chlorine or that has been treated with another effective o...

Reviews: