BRUSH SYSTEM CONTINUED
SYMPTOM
POSSIBLE CAUSE
SOLUTION
Brush
will not turn when
Trigger Switch
is activated, but will turn freely by hand.
2.
Brush Motor Circuit Breaker
has
tripped.
2. Insure that
Brush (10013)
turns
freely by hand. Reset
Circuit Breaker
(10113).
NOTE:
If
Brush
does not turn
freely by hand inspect
Brush Assembly
(18210). (See Repair Manual:
Removing Brush Assembly, and
Rebuilding Brush Assembly).
3. Loose
Wire, Lever Nut
or
Terminal
connection.
3. Reconnect loose
Lever Nut (10267 /
10277)
or replace
Spade Terminal
.
4. Broken
Gear Belt.
5. Replace
Gear Belt (10011).
5. Slipping
Pulley (10010).
6. Reattach
Pulley (10010)
to
Brush
Shaft (10012)
ensuring set screws and
dimples in
Brush Shaft (10012)
align.
Brush
will NOT turn when
Trigger
Switch
is activated and will not turn by
hand.
1. Debris clogging
Bearing Assy
/
seized
Bearings
.
1. Remove
Brush Assembly (18210)
Clean/replace:
Bearings (10017),
Bearing Block (10195), Brush Washer
(10183)
.
2. Seized
Brush Motor
.
2. Replace
Brush Motor (18005).
Also
inspect
Brush Assembly (18210).
Brush Motor
runs continuously.
1. Defective
Trigger Switch.
NOTE:
A
defective
Trigger Switch
will run
Brush
Motor
continuously but may operate the
Pump
normally.
1. Replace the
Trigger Switch (18032).
12
Summary of Contents for C4-100A
Page 1: ...Maintenance Repair Manual Models C4 100A C4100LM C4 UPBLMDeepCleaningExtractors ...
Page 2: ...7001 ...
Page 20: ...Models C4 100A C4100LM C4 UPBLM Parts List and Diagrams ...
Page 21: ...18 ...
Page 23: ...20 ...
Page 25: ...22 ...
Page 27: ...24 ...
Page 29: ...26 ...
Page 30: ...27 ...
Page 31: ...28 ...
Page 32: ...29 ...
Page 35: ...32 ...
Page 37: ...34 ...
Page 39: ...36 ...
Page 41: ...38 ...
Page 42: ...39 ...