RECOVERY WATER SYSTEM
SERVICE MANUAL
ENGLISH
Razor SV17 - Razor E17
909 6577 000(4)2009-11
25
RECOVERY WATER SYSTEM
TANK AND VACUUM GRID WITH FLOAT CLEANING [Razor SV17 - Razor E17]
Drive the machine to the appointed disposal area.
1.
Check that the switches (5 and 6) are turned to “0”.
2.
If necessary, empty the tank (43) by means of the hose (22).
3.
Lift the cover (41), then wash with clean water the cover, the tank (43) and the vacuum grid (46).
4.
Drain the water in the tank through the hose (22).
If necessary, release the fasteners (A) and open the grid (B), recover the float (C), clean all the components and then reinstall
5.
them.
Check the recovery water tank cover gasket (D) for integrity.
6.
NOTE
The gasket (D) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If necessary replace the gasket (D) after removing it from its housing (E).
When assembling the new gasket, install its joint (F) in the central area, as shown in the figure.
Check the gasket (G) bearing surface (D) for integrity and sealing capabilities.
7.
Check the compensation hole (H) for clogging.
8.
NOTE
The hole (H) compensates the air in the cover interspaces, thus allowing the creation of vacuum in the recovery
water tank.
Close the cover (41).
9.
S301372