background image

15 

WARNING:

  Activate  the  opener  only  when  gate  is  in  full  view,  free  of  obstruction  and  properly 

adjusted.  No  one  should  enter  or  leave  gate  area  while  gate  is  in  motion.  Do  not  allow  children  to 

operate push button or remote. Do not allow children to play near the door. 

Your  swing  gate  opener  receiver  and  remote  control  transmitter  are  set  to  a  matching  code.  If  you 

purchase additional remote controls, the gate opener must be programmed to accept the new remote 

code. 

 

Caution:

 If you lose one of any remote control, please learn all other remote controls to have a new 

code for safety. 

 

The 

BROWN

 

wire of the external receiver should be connected into the “19” terminal. 

The 

BLACK

 

wire of the external receiver should be connected into the “20” terminal. 

The 

RED

 wire of the external receiver 

should be connected into the “9” terminal. 

Wired Keypad (24VDC) (optional) 

The 

RED

 

wire of the wired keypad should be connected into the “9” terminal. 

The 

BLACK

 

wire of the wired keypad should be connected into the “14” terminal. 

The 

WHITE

 wire of the wire

d keypad should be connected into the “19” terminal. 

The 

BLUE

 

wire of the wired keypad should be connected into the “20” terminal. 

Solar Panel (optional) 

Please refer to the manual instruction of solar panel and controller (

KNL

118) separated. 

 

 

How to learn or erase the remote 

Learn the remote 

Press and release the learn button, the 

LED

 will display 

“Ln”,

 then press the key in the remote twice in 2 

seconds,  the 

LED

  will  flash

 

“Ln”

  for  4  seconds  then  back  to 

“-  -”

.  Now  the  remote  has  been  learnt 

successfully. 

 

 

 

 

 

 

 

Erase all the remote codes 

Press  and  hold  the  learn  button  until  the 

LED

 

display “

dL

”, then release the learn button , the 

LED

  will 

display back to 

“- -”

. Now all remote codes have been erased. 

 

 

 

 

 

 

 

 

Summary of Contents for KNL502+

Page 1: ......

Page 2: ...e Opener s Base Plate 8 Step 6 Install the Gate Bracket 8 Step 7 Set the Limit Switches of the opener at left side 9 Step 8 Set the Limit Switches of the opener at right side 10 Mounting the Control B...

Page 3: ...njury or death 1 READ AND FOLLOW ALL INSTRUCTIONS 2 Installation should be performed by a professional installer 3 Should electricity be required use a certified electrician only 4 Never let children...

Page 4: ...2 Parts List...

Page 5: ...essories Parts List Tools Needed Power Drill Tape Measure Level Hammer C Clamps Wire Strippers Phillips Screwdriver Hex Key Wrench 6mm Open End Wrenches 14 17 or Adjustable Wrenches An extra person sh...

Page 6: ...orrectly and properly installed and in good smooth Features Soft start and soft stop Emergency release key in case of power failure Dual Single gate running mode Adjustable opening closing interval be...

Page 7: ...ion of swing Gate opener We suggest that you become familiar with instructions and illustrations in this manual This will help insure that your installation is performed in an efficient and profession...

Page 8: ...6 Step 2 Assemble Arms Step 3 Attach the Arms to Gate Opener Step 4 Determining the mounting positions...

Page 9: ...7...

Page 10: ...8 Step 5 Install the Opener s Base Plate Step 6 Install the Gate Bracket...

Page 11: ...on Rotate the Bottom Collar until after hearing a click of Bottom Limit Switch s contact And then tighten the screw of Bottom Collar Set the left opened Limit Switch Loosen the screw of Top Collar Pus...

Page 12: ...Rotate the Top Collar until after hearing a click of Top Limit Switch s contact And then tighten the screw of Top Collar Set the right opened Limit Switch Loosen the screw of Bottom Collar Push the r...

Page 13: ...ontrol box use the deck screws not provided Ensure the control box is installed in a secure surface and at least 100 cm 40 inches above the ground to protect it from rain snow etc which probably cause...

Page 14: ...s 1 5m length are provided Other cables are subject to site installation requirement and not provided CAUTION Make sure the cable outlet hole in the Control Box is always down during installation so a...

Page 15: ...13 Connecting of the control board For Pull to Open...

Page 16: ...nstalled in the Master Gate and ARM 2 is installed in the Slave Gate Alarm Lamp optional The red wire of the alarm lamp should be inserted into either LAMP 11 terminal the white wire into the other on...

Page 17: ...RED wire of the external receiver should be connected into the 9 terminal Wired Keypad 24VDC optional The RED wire of the wired keypad should be connected into the 9 terminal The BLACK wire of the wi...

Page 18: ...Interval between Master Slave Gate Setting The open interval can be adjusted by pressing the INC and DEC Buttons respectively The Digital Display will show 0 9 which indicates the interval time 0 mea...

Page 19: ...is adjusted by pressing INC and DEC buttons respectively The Digital Display will show 1 9 which indicates the stall force levels 1 means the minimum force and 9 is the maximum force Each time you pr...

Page 20: ...dicate Pb 10 Set the Period of Soft Start When the Digital Display indicates Pb the gate opener is ready for setting period of soft start You can press the INC or DEC button to set the period of soft...

Page 21: ...ess and release the remote control the gate will move to the programmed closing position and stop While the gate is moving press and release the remote control the gate will stop moving immediately Th...

Page 22: ...control board The MOTOR terminal should be connected to the MOTOR2 terminal of the control board The DN terminal should be connected to the DLT2 terminal of the control board The COM terminal should b...

Page 23: ...AC input is connected Check if the fuse in control board is bad 2 Opener powers up but does not run Arm cable loose or disconnected Verify that all of the wires going to the arm are secure and that th...

Page 24: ...motor cable is away from sources of electrical interference such as electric fences power lines etc 6 Gate opens closes or stops on its own Ensure that the key for manual release is in the lock positi...

Page 25: ...23 Quick Setting Guide...

Page 26: ...24...

Page 27: ...25...

Page 28: ...26...

Page 29: ...27...

Reviews: