14
Note: Ensure the power is OFF before the connecting of the control board.
Note: You should use the five core cable with PVC sheath to connect the articulated arm to the
main control board. Wires in the five core cable used to connect the motor should be greater than
1mm
2
(16AWG). Wires in the five core cable used to connect the limit switches should be greater
than 0.3mm
2
(22AWG).
Arm 1 (Installing in the left side)
Use the five core cable to connect the arm to the control board. The
MOTOR+
terminal of the arm should
be connected to the
MOTOR1-
terminal of the control board. The
MOTOR-
terminal should be connected to
the
+MOTOR1
terminal of the control board. The
DN
terminal should be connected to the
DLT1
terminal of
the control board. The
COM
terminal should be connected to the
COM
terminal of the control board. The
UP
terminal should be connected to the
ULT1
terminal of the control board.
Arm 2 (Installing in the right side)
Use another five core cable to connect the arm 2 to the control board. The
MOTOR+
terminal of the arm
should be connected to the
+MOTOR2
terminal of the control board. The
MOTOR-
terminal should be
connected to the
MOTOR2-
terminal of the control board. The
DN
terminal should be connected to the
ULT2
terminal of the control board. The
COM
terminal should be connected to the
COM
terminal of the
control board. The
UP
terminal should be connected to the
DLT2
terminal of the control board.
NOTE: It is recommended that ARM 1 is installed in the Master Gate, and ARM 2 is installed in the Slave
Gate.
Alarm Lamp (optional)
The red wire of the alarm lamp should be inserted into either
LAMP (#11)
terminal, the white wire into the
other one
(#12)
.
Back-up Battery (optional)
The
“24V+”
of the battery should be wired to the
BAT+ (#13)
ter
minal, “24V-” should be wired to
“BAT-”
(#14)
terminal.
Recommend strongly to use the controller
KNL
118 (WA4004
)
to connect Battery with battery’s
Terminal of control board if the battery is used as the primary power supply in system (such as SOL
PLUS KIT). Please refer to the user manual of control
KNL
118
(
WA4004
)
separated.
Photocell Beam System (PBS) (optional)
Use a 2-core cable to connect the
“- ~”
terminal of the photocell’s emitter to the “14” terminal, the
“+ ~”
terminal to the “9” terminal. Also the
“- ~”
and
“+ ~”
terminals of the photocell’s receiver should be
connected to the “16” and “17” terminals in parallel.
Use another 2-core cable to connect the
“COM”
terminal of the receiver to the “17” terminal, the
“NC”
terminal to the “18” terminal.
Push Button (optional)
The red wire should be inserted into either
O/S/C
terminal, the white wire into the other one.
Loop Detector (optional)
First insert the
LOOP DETECTOR BOARD
into the
CONTROL BOARD
, and then connect the
LOOP
DETECTOR
to the control board. Detailed instruction please refers to the manual instruction of
LOOP
DETECTOR
separated.
Exit Wand (optional)
First insert the
EXIT WAND BOARD
into the
CONTROL BOARD
, and then connect the
EXIT WAND
to the
control board. Detailed instruction please refers to the manual instruction of
EXIT WAND
separated.
Electric Lock (optional)
The electric lock should be wired to the
“LOCK”
terminal.
External Receiver (optional)
Summary of Contents for KNL502+
Page 1: ......
Page 4: ...2 Parts List...
Page 9: ...7...
Page 10: ...8 Step 5 Install the Opener s Base Plate Step 6 Install the Gate Bracket...
Page 15: ...13 Connecting of the control board For Pull to Open...
Page 25: ...23 Quick Setting Guide...
Page 26: ...24...
Page 27: ...25...
Page 28: ...26...
Page 29: ...27...