REMOVING THE DRIVE MOTOR AND BELT SWITCH
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Remove the cabinet front (see page 4-6
for the procedure).
4. Remove the belt and drum from the dryer
(see page 4-15 for the procedure).
5.
To remove the drive motor:
a) Remove the nut from the drive motor
flywheel and remove the flywheel.
Drive Motor
Flywheel
b)
Single Motor Models Only:
Remove
the blower fan belt from the blower pul-
ley.
NOTE:
It is important that you re-
install the belt properly to prevent the
blower from turning backwards. The
post on the blower housing (see step 5
on page 4-17) will interfere with the belt
if it is installed incorrectly.
c) Lift the top and bottom locking tabs on
the drive motor connector and pull the
connector off the motor.
Top Locking Tab
Drive Motor
Connector
Blower Fan
Belt
Belt Switch
Continued on the next page.