Thank You for purchasing this water heater. Properly
installed and maintained, it should give you years of trouble
free service.
Abbreviations Found In This Instruction Manual:
• CSA - Canadian Standards Association
• ANSI - American National Standards Institute
• NFPA - National Fire Protection Association
• ASME - American Society of Mechanical Engineers
• GAMA - Gas Appliance Manufacturer’s Association
• UL - Underwriters Laboratories Inc.
This gas-fi red water heater is design certifi ed by CSA
International under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.3 • CSA
4.3 (current edition).
PREPARING FOR THE INSTALLATION
Read the “General Safety” section, of this manual
first and then the entire manual carefully. If you
don’t follow the safety rules, the water heater will not
operate properly. It could cause DEATH, SERIOUS
BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of the gas-fi red water
heater. You must read and be aware of the warnings
placed throughout the manual. All warnings and all
instructions are essential to the proper operation of
the water heater and your safety. Since we cannot put
everything on the fi rst few pages, READ THE ENTIRE
MANUAL BEFORE ATTEMPTING TO INSTALL OR
OPERATE THE WATER HEATER.
The installation must conform with these instructions
and the local code authority having jurisdiction. In
the absence of local codes, the installation must
comply with the current editions of the
National Fuel
Gas Code, ANSI Z223.1/NFPA 54
and the
National
Electrical Code, NFPA 70
. Documents are available
from:
Canadian
Standards
Association,
5060 Spectrum Way,
Mississauga, Ontario, Canada
L4W
5N6
NFPA documents are also available from:
National Fire Protection Association,
1 Batterymarch Park,
Quincy, MA 02269.
The water heater when installed must be grounded in
accordance with the local codes, or in the absence of
local codes: the National Electrical Code (NFPA 70).
I f a f t e r r e a d i n g t h i s m a n u a l y o u h a v e a n y
questions or do not understand any portion of
the instructions, call the local gas utility or the
manufacturer whose name appears on the rating plate.
1.
2.
3.
4.
Carefully plan the place where you are going to put
the water heater. Correct combustion, vent action, and
vent pipe installation are very important in preventing
death from possible carbon monoxide poisoning and
fi res (see Figures 1 and 3). Examine the location to
ensure the water heater complies with the “Facts to
Consider About Location” section in this manual.
For California installation this water heater must be
braced, anchored, or strapped to avoid falling or
moving during an earthquake. See instructions for
correct installation procedures. Instructions may be
obtained from California Offi ce of the State Architect,
1102 Q Street, Suite 5100, Sacramento, CA 95811.
Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR
2.00: State Plumbing Code and 248-CMR 5.00, See
page 11.
Complies with SCAQMD rule #1146 and districts
having equivalent NOx requirements.
Complies with California’s legislation AB1953 and
Vermont’s legislation Act 193 requirement of a
weighted average maximum of 0.25% lead.
5.
6.
7.
8.
9.
INTRODUCTION