All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts or washers
used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened.
This information is intended for use by individuals possessing adequate background of electrical, electronic and mechanical experience.
Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be
responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
Minimum Compressor Capacity Vacuum ...................................21 in
Minimum Equalized Pressure
@70°F......................................................................49PSIG
@90°F......................................................................56PSIG
Refrigerant R134a................................................................. 4.2
.
oz
Compressor ................................................................... 700 BTU/hr
Clearance must be provided at top, sides and rear of the refrigerator
for air circulation.
AT TOP..........................................................................................1 in
AT SIDES.................................................................................. 1/8 in
AT REAR.......................................................................................1 in
E L E C T R IC A L S P E C IF IC AT IO N S
...................................................................................................................
-6°F
to
+8
°F
Defrost Control ...................................................................................................................................................................................Automatic
Defrost Thermostat .....................................................................................................................................................................................50°F
Electrical Rating : 115VAC, 60Hz...............................................................................................................................................................1- 5 A
Maximum Current Leakage .....................................................................................................................................................................0.5mA
Maximum Ground Path Resistance ..................................................................................................................................................0.14 Ohms
Energy Consumption....................................................................................................................................22 cu.ft. 466 kWh/yr (Energy Star)
C o n tr o l P o s it io n : M ID /M ID
And Ambient of:
70°F
Fresh Food, °F............................................................... 33°F
to
41°F
Frozen Food, °F..............................................................
Percent Running Time........................................................
90°F
......................................................................................
......................................................................................
.......................................................................................
-4°F to +4°F
25%-35%
45%-60%
33°F to 41°F
-4°F to +4°F
....
1-1 DISCONNECT POWER CORD BEFORE SERVICING IMPORTANT:
RECONNECT ALL GROUNDING DEVICES.
1-2 IMPORTANT NOTICE
1.3
1-4 NO LOAD PERFORMANCE
1-5 REFRIGERATION SYSTEM
1-6 INSTALLATION
1. SPECIFICATIONS
- 3 -
Freezer Temperature Control (Middle setting)
Summary of Contents for 795.78302.800
Page 34: ...8 5 MAIN PWB ASSEMB LY AND PARTS LIST 34 TOP VIEW BOTTOM VIEW ...
Page 35: ...8 6 PWB DIAGRAM 8 6 1 PWB Main Assembly 35 ...
Page 36: ... 36 ...
Page 66: ...JUL 2008 ...