- 17 -
6-2 PTC/COMBO AND OLP
Shows continuity
Open
Separate PTC-Starter/Combo
from Compressor and
measure resistance
between No. 5 and 6
of PTC-Starter with a
Tester.
(Figure 19a and 19b)
Observation value is
115V/60Hz : 6.8 ±30%
The resistance value
is 0 (short) or
8(open).
Check another
electric component.
Replace OLP.
Replace PTC-
Starter/Combo
Normal operation of
compressor is impossible
or poor.
Separate OLP from
compressor and check
resistance value between
two terminals of OLP with a
tester.
(Figure 20)
at room temperature
PTC/Combo OK
OLP OK
6
5
Figure 19a
Figure 19b
Figure 20
?