11-7 Damper
Function
The damper supplies the cold air from freezer room to chillroom by using the damper plate.
Chillroom gets colder when damper plate is open. When damper plate is close, chillroom
temperature will rise
How to
Measure
< Damper Circuit >
< extension >
Check the ,
Standard
Damper
Test Points
Red and Yellow
Result
373 ~ 456
Ω
Test Points
Blue and White
Result
373 ~ 456
Ω
Check the resistance between connectors 1,3 and 2,4.
It means that check electric current is flowing.
If there is resistance, damper is normal.