- 32 -
0
Ω
OFF
Other
Short
Open
Normal
Change the sensor
possible open harness
in cabinet
Check the Temp and
resistance (Table-1)
Result
SVC Action
8. Troubleshooting With Error Display
8-1 Freezer Sensor Error (Er FS)
No
1
2
Checking flow
Check for a loose connection.
Check the Blue/White to
Blue/White.
Result & SVC Action
<CON7>
<Temperature table-1>
(1) To (2)
-22°F
/ -30
°C
-13°F
/ -25
°C
-4°F
/ -20
°C
5°F
/ -15
°C
14°F
/ -10
°C
23°F
/ -5
°C
32°F
/ 0
°C
Result
40
㏀
30
㏀
23
㏀
17
㏀
13
㏀
10
㏀
8
㏀
※
The sensor is determined by
the temperature.
For example, 23
㏀
indicates -4°F.