12
Method2
The dryer must be connected to the cold water faucet using the
new inlet hoses. Do not use old hoses.
1.
If “Y” connector cannot be attached directly to the cold
water faucet, the short hose must be used.
2.
Turn the cold water faucet off.
3.
Attach short inlet hose to cold water faucet.
Screw on coupling by hand until it is seated on the faucet.
4.
Using pliers, tighten the coupling with an additional two-
thirds turn.
Do not overtighten, as it may damage the coupling.
5.
Attach ‘Y” connector to brass male end of small hose. Screw
on coupling by hand until it is seated on connector.
6.
Using pliers, tighten the coupling with an additional two-
thirds turn.
Do not overtighten, as it may damage the coupling.
7.
Attach angled end of long hoses to the fill valve at the
bottom of the dryer rear frame. Screw on coupling by hand
until it is seated on fill valve connector.
8.
Using pliers, tighten the coupling with an additional two-
thirds turn.
Do not overtighten, as it may damage the coupling.
9.
Check that the water faucets are on.
10.
Check for leaks around “Y” connector, faucets and hoses.
Level Dryer
To set the dryer to the same height as the washer, fully retract
the leveling feet by turning them counterclockwise, then loosen
the legs by turning them clockwise
Adjust the leveling feet only as much as necessary to level the
dryer. Extending the leveling feet more than necessary can
cause the dryer to vibrate.
Then loosen
Retract fully
Tuyau court
(arrivée d’eau
froide)
Raccord en Y
Tuyau long
>%(67@$B(1BYLQGG
Summary of Contents for 592-89032