FEATURES AND BENEFITS
Key Parts and Components
WARNING
Install this appliance in accordance with National Electric Code guidelines.
Air Filter
Front
Grille
Air Intake
(Inlet Grille)
Air Discharge
Cabinet
Upper
Guide
Remote Control
QR code emblem
(For establishing
smart app connection)
Horizontal
Air Deflector
(Vertical Louver)
Vertical Air Deflector
(Horizontal Louver)
Evaporator
Brace
Compressor
Condenser
Base Pan
Power Cord
Electrical Data
120 V
240 V
RESET
TEST
RESET
TEST
RESET
TEST
Power cord may include a current interrupter device.
Test and reset buttons are provided on the plug case.
Periodically test the device by first pressing TEST and
then RESET. If the TEST button does not trip or if the
RESET button will not stay engaged, stop using the air
conditioner and contact a qualified service technician.
WARNING
Never push the test button during operation.
Doing so can damage the plug.
Do not remove, modify, or immerse this plug. If
this device trips, the cause should be corrected
before further use.
CAUTION
The conductors inside this cord are surrounded
by shields, which monitor leakage current.
These shields are not grounded. Periodically
examine the cord for any damage. Do not use
this product in the event the shields become
exposed. Avoid shock hazard. This unit cannot
be user-serviced. Do NOT open the tamper-
resistant sealed portion. All warranties and
performance will be voided.
BTU & Wall Receptacle
Power Supply
15000 BTU
Use 15 A, time-delay fuse
or 15 A circuit breaker.
Standard 120 V, 3-wire
grounding receptacle rated
15 A/120 VAC/60 Hz
18000 BTU
Standard 240 V, 3-wire
grounding receptacle rated
15 A/240 VAC/60 Hz
25000 BTU
Use 20 A, time-delay
fuse or 20 A circuit
breaker.
Standard 240 V, 3-wire
grounding receptacle rated
20 A/240 VAC/60 Hz
WARNING
DO NOT USE EXTENSION CORDS RISK OF
FIRE, SERIOUS INJURY OR DEATH.
x
Do not use an extension cord with this
product.
x
Do not use surge protectors or multi-outlet
adapters with this product.