background image

 

12

 

 
 

 
 

 
 

 
 

 

 

 
 
The cold extract air has to be vented out of the room via the air hose. This can be executed via a tilted 

window, a door or wall aperture. Make sure that no cold outside air can enter the room. 
 
Set the function to “HEATING“. The settable temperature range is between 15°C and 25°C. You can set this 

using the temperature control. 
 

Note: In the heating mode, the ventilation level is already preset to ensure efficient heating of ambient 
air. You will not be able to adjust the fan speed. 

 

DEHUMIDIFYING MODE 

Humidity is extracted from the air, collected in the water tank and discharged via the condensation water 
outlet.   

 

 

Set the function to “Dehumidify”. 

 

 

Remove the rubber plug of the condensation water outlet (shown on picture below) on the side of 
the unit and attach the drainage hose.  

 

 

Allow water to flow out continuously into a bucket or floor drain in order to achieve higher 

dehumidification capacity. In the dehumidify mode, you must not feed the room air outside with the 
extract air hose. 

 

 

 
 

 

 
 

 
 

 
Note: In the dehumidify mode, the ventilation level is already preset to ensure efficient 

dehumidification of ambient air. You will not be able to adjust the fan speed. 
 

IF A FLOOR DRAIN IS UNAVAILABLE TURN THE UNIT OFF AND PLACE A POT OR PAN DIRECTLY 
BENEATH THE LOWER DRAIN OUTLET. DO NOT LEAVE THE UNIT UNATTENDED WHILE IT IS DRAINING 

IN CASE THE POT OR PAN FILLS AND NEEDS TO BE REPLACED. 
 

 
 

 

 

A)

 IMPORTANT 

 

Be sure to turn the unit OFF and unplug the unit before cleaning or servicing. 

 

Do not use gasoline, thinner or other harsh chemicals to clean the unit. 

 

Never wash the unit directly under a tap or with a hose.   

 

Do not allow water to enter into the air conditioner.  

CLEANING & MAINTENANCE  

Summary of Contents for 35132

Page 1: ...1 Kenmore 12 000 BTU Portable Air Conditioner Dehumidifier Heater with Remote Control Use Care Guide Model 35132 FOR HOUSEHOLD USE ONLY ...

Page 2: ...ause circuit failure Changing the outlet without making the appropriate wiring changes will create an unsafe condition that could result in fire or electrical shock Refer all such work to a licensed and qualified electrician WARNING This appliance must be properly grounded The power cord of this appliance is equipped with a three prong LCDI plug To minimize the risk of electric shock use the plug ...

Page 3: ...ed period of time could be hazardous to your health Do not use this air conditioner for non specified refrigeration purposes e g preserving precision devices food pets plants and art objects Such usage could cause damages to them Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices The air conditioner is a consumer comfort appliance...

Page 4: ...king carton It is recommended to keep the carton and packing material for storage or transportation of the unit Hose Drain hose For continuous drainage Remote sensor kit used only in out of room cooling mode Window slider kit 3pcs 2 AAA batteries Remote Control PARTS OF THE AIR CONDITIONER ACCESSORIES UNPACKING INSTRUCTIONS Figure 1 Figure 2 Front of Unit Figure 1 1 Control panel 2 Remote receiver...

Page 5: ... the wall or other obstacles such as furniture The plug should be easily accessed after the appliance is positioned 3 If the unit is to be placed outside of the room to be cooled you should try to position the unit on a flat solid surface and in an area protected from rain and sun exposure such as sunroom veranda or hallway You should not operate the unit in moist areas such as e g saunas or simil...

Page 6: ... TEST and the other is marked RESET Press the TEST button you will hear a click as the RESET button pops out 3 Press the RESET button you will hear a click as the button engages 4 The power supply cord is now energized and supplying electricity to the air conditioner it is indicated by a light on the plug head Under no circumstances should this device be used to turn the unit on or off The RESET b...

Page 7: ...perature of 25 C 4 TEMP Pressing this button in cooling mode adjusts the required room temperature by 1 C to a minimum temperature of 17 C Pressing this button in heating function adjusts the required room temperature by 1 C to a minimum temperature of 15 C 5 LED DISPLAY The display shows the current ambient temperature in operation By pressing the or buttons the required target temperature is dis...

Page 8: ...xpired the delayed start up will be cancelled the unit turns on and can be operated in the required operating mode How to program a delayed shutdown This function is used to set the number of hours delay before the appliance goes off Proceed as follows Start the unit in required function cooling heating or dehumidifying Press the TIMER button during operation and enter the required number of hours...

Page 9: ...on the appliance Reception is confirmed by a beep from the main unit The remote control will not operate if curtains door or other material block the signal from the receiver to the remote control Prevent any liquid from falling into the remote control Do not expose the remote control to direct sunlight or heat if the infrared signal receiver on the indoor unit is exposed to sunlight the air condi...

Page 10: ...con The warm extract air must be emitted from the room via the exhaust hose Make sure that no warm outside air can enter the room For effective cooling we recommend our selection of various accessories which reduce or prevent entry of warm air into the room Set the function to COOLING Set the target temperature using the temperature control The target temperature can range between 17 C and 30 C 65...

Page 11: ...g cooled by pushing it into the hole The sensor must face the room being cooled and be positioned above the air outlet 3 Remove the plastic cover from the remote sensor jack on the main body of the unit found near the top of the front of the unit Keep it for later use 4 Attach the end of the supplied cable to the jack on the main unit Organize the wire so it will not get damaged stepped on or pinc...

Page 12: ...ide of the unit and attach the drainage hose Allow water to flow out continuously into a bucket or floor drain in order to achieve higher dehumidification capacity In the dehumidify mode you must not feed the room air outside with the extract air hose Note In the dehumidify mode the ventilation level is already preset to ensure efficient dehumidification of ambient air You will not be able to adju...

Page 13: ...NDED PERIOD OF NON USE If the air conditioner will not be used for a long period of time remove the bottom rubber plug from the back hole and attach a section of the Continuous Drain Hose and completely drain the unit of water Follow cleaning instructions A D Perform reverse Installation Instructions Repack the unit in its original package and store upright in a cool dry place Important Always sto...

Page 14: ...g the air from being discharged Position the air hose correctly keeping it as short and free of curves as possible to avoid bottlenecks Check and remove any obstacles obstructing air discharge Room is not cool enough Windows doors in room are open There are heat sources nearby Exhaust air duct is not connected or is blocked Temperature setting is too high Air filter blocked by dust Close all windo...

Page 15: ...he unit requires qualified inspection E2 Temperature of the cooling agent lines too high or too low Temporary error on measuring output temperature Please switch the TRANSFORM unit off and start it again after approx 30 minutes If the error occurs continuously the unit requires qualified inspection E3 Incorrect signal This error message in the cooling function refers to too high ambient temperatur...

Page 16: ...rs compressor only Implied Warranties Any implied warranties which the purchaser may have are limited in duration to 1 year for parts and 5 years for the compressor only from the date of purchase This limited warranty is in lieu of all other warranties expressed or implied including warranties of merchantability and fitness for a particular purpose and excludes all liability for incidental or cons...

Reviews: