background image

Operation

5

T OUCH PAD

ELECTRONIC CONTROL

Air Conditioner Features

Before you begin, thoroughly familiarize yourself with the control panel and remote as shown below and all its functions, then 
touch the symbol pads for the functions you desire. 

The unit can be controlled by the panel touch pads or with the remote control.

Turn Remote Control upside down. Squeeze tab and pull 
to remove battery tray. Place battery in tray with 
POSITIVE(“+”) side facing UP, according to diagram. 
Re-insert battery tray.

TO REPLACE BATTERY

Battery Size

: CR2025

ACTIVATES
TIMER

SLEEP MODE

FILTER RESET
BUTTON

TURNS UNIT
ON OR OFF

ADJUSTS
TEMPERATURE
OR TIME

SETS FAN SPEEDS

DISPLAYS
TEMPERATURE/TIME

SETS MODE

REMOTE CONTROL

ON/OFF

ADJUSTS
TEMP & TIME

AUTO FAN

SLEEP
MODE

SETS FAN

SPEEDS

ACTIVATES
TIMER

INFRARED
REMOTE WINDOW

TAB

CAUTION

1. Be sure the batteries are inserted properly.
2. Do not use batteries other than the type specified. 
3. Do not use old batteries with new ones.
4. Do not dispose of batteries in fire. Batteries may explode or leak.

Summary of Contents for 253.35006

Page 1: ...enmore CLIMATISEUR DE TYPE FENÊTRE Sears Brands Management Corporation Hoçman Estates IL 60179 U S A www kenmore com www sears com English Français Use Care Guide Manuel d utilisation et d entretien Models Modèles 253 35305 253 35308 253 35310 253 35312 ...

Page 2: ...ted to filters 2 Service related telephone calls or technician visits relating to a user s requirements for instructions involving the correct product installation operation or regular maintenance to the product i e cleaning filters and the like 3 Maintenance adjustments and cleaning inquiries or service calls 4 Damage or failure when installation operation and maintenance instructions provided ar...

Page 3: ...t connecting tubing and the compressor will be covered free of charge if defective in material or workmanship 3 If this appliance is ever used for other than private family residential purposes this warranty only applies for 30 days from the date of purchase Service Type Kenmore window and portable air conditioner units are serviced on a carry in basis whereby customer brings the unit to a Sears R...

Page 4: ...ars at 1 800 4 MY HOME Prevent Accidents To reduce the risk of fire electrical shock or injury to persons when using your air conditioner follow basic precautions including the following If the air conditioner is to be installed in a window you will probably want to clean both sides of the glass first If the window is a triple track type with a screen panel included remove the screen completely be...

Page 5: ...tery in tray with POSITIVE side facing UP according to diagram Re insert battery tray TO REPLACE BATTERY Battery Size CR2025 ACTIVATES TIMER SLEEP MODE FILTER RESET BUTTON TURNS UNIT ON OR OFF ADJUSTS TEMPERATURE OR TIME SETS FAN SPEEDS DISPLAYS TEMPERATURE TIME SETS MODE REMOTE CONTROL ON OFF ADJUSTS TEMP TIME AUTO FAN SLEEP MODE SETS FAN SPEEDS ACTIVATES TIMER INFRARED REMOTE WINDOW TAB CAUTION ...

Page 6: ...t will automatically go to the highest speed The fan speed will re adjust back to the slowest speed as the room returns to the original set temperature To operate on Fan Only press the MODE button to select Use Fan Only function to circulate room air without air conditioner cooling You can use any fan speed you prefer and the actual room temperature will be displayed in the DISPLAY To use Cool pre...

Page 7: ... will save energy usage in this mode The compressor and motor will turn off once the room is at the desired temperature The air will be sampled for 20 seconds every 10 minutes until the room is above the set temperature at which point the compressor turns back on and the fan runs The entire process is now repeated Press the UP and DOWN arrows to select the desired time up to 24 hrs The control wil...

Page 8: ...h a key hole overflow drain hole can use drain kit 5304481680 to connect a 1 2 inch drain hose for safe disposal of excess system water This part can be ordered at www SearsPartsDirect com There is a 2 Second delay for the compressor shutting down when selecting FAN ONLY This is to cover the possibility of having to roll through to select another mode FRESH AIR VENT CONTROL On 253 35310 253 35312 ...

Page 9: ...ughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation...

Page 10: ...E AIR CONDITIONER TURNS ON AND OFF BY ITSELF Check if Then Outside temperature is extremely hot Set fan speed at the fastest setting for maximum cooling Page 6 Timer turned unit ON or shut unit OFF Push ON OFF Button to turn unit ON or OFF Page 6 THE AIR CONDITIONER DOES NOT COOL THE ROOM ICE BEHIND FRONT PANEL Check if Then Outside temperature is below 16 C Set mode to FAN ONLY and fan speed to f...

Page 11: ...gerant passing through evaporation Page 11 Gurgling or hissing sounds Beeping Electronic Control Normal noise when electronic control settings are changed Vibration Unit Vibration Due to poor wall or window construction or incorrect installation Page 11 Room Air Conditioner Troubleshooting Guide Normal Sounds High Pitched Whine Today s high efficiency compressors may have a high pitched whine duri...