background image

Saf

ety

Instructions

4

Important Safety
Instructions

Read all instructions before using this air conditioner.

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.

Unit must be upright for one hour prior to operating.

Plug in &
press RESET

The power supply cord contains a current device that senses damage to the 
power cord.
To test your power supply cord do the following:

1.  Plug in the Air Conditioner.
2.  The power supply cord will have TWO buttons on the plug head. Press the 
TEST button. You will notice a click as the RESET button pops out.
3.  Press the RESET button. Again you will notice a click as the button engages.
4.  The power supply cord is now supplying electricity to the unit. (On some 
products this is also indicated by a light on the plug head).

WARNING

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance. Read product labels for flammability and other warnings.

The power supply cord with

this air conditioner contains a current
detection device designed to reduce the risk of
fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired, and it must
be replaced with a cord from the Product
manufacturer.

Avoid fire hazard or electric

shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from
the power cord.

Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the 
TEST button is pushed, or it cannot be reset. A new one can be obtained by
contacting Sears at 1-800-4-MY-HOME

®

.

If power supply cord is damaged, it CANNOT be repaired. It MUST be 
replaced by one obtained by contacting Sears at 1-800-4-MY-HOME

®

.

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air
conditioner, follow basic precautions, including the following:

If the air conditioner is to be installed in a window, you will probably want to 
clean both sides of the glass first. If the window is a triple-track type with a 
screen panel included,remove the screen completely before installation. 
Be sure the air conditioner has been securely and correctly installed according
to the separate installation instructions provided with this manual. Save this 
manual and the installation instructions for possible future use in removing or 
reinstalling this unit. 
When handling the air conditioner, be careful to avoid cuts from sharp metal 
fins on front and rear coils.

Electrical Information

The complete electrical rating of your new room air conditioner is stated on the serial
plate. Refer to the rating when checking the electrical requirements.

Be sure the air conditioner is properly grounded. To minimize shock and fire
hazards, proper grounding is important. The power cord is equipped with a
three-prong grounding plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the
wall receptacle you intend to use is not adequately grounded or protected by a
time delay fuse or circuit breaker, have a qualified electrician install the proper
receptacle.
Do not run air conditioner without outside protective cover in place. This could
result in mechanical damage within the air conditioner.

Do not use an extension cord or an adapter plug.

Do not, under any
circumstances, cut,
remove, or bypass the
grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

Grounding type wall
receptacle

Operation of Current
Device

WARNING

WARNING

WARNING

NOTE

NOTES:

Be sure the electrical service is adequate for the model you have chosen. This
information can be found on the nameplate, which is located on the side of the
cabinet.

Summary of Contents for 253.35006

Page 1: ...enmore CLIMATISEUR DE TYPE FENÊTRE Sears Brands Management Corporation Hoçman Estates IL 60179 U S A www kenmore com www sears com English Français Use Care Guide Manuel d utilisation et d entretien Models Modèles 253 35305 253 35308 253 35310 253 35312 ...

Page 2: ...ted to filters 2 Service related telephone calls or technician visits relating to a user s requirements for instructions involving the correct product installation operation or regular maintenance to the product i e cleaning filters and the like 3 Maintenance adjustments and cleaning inquiries or service calls 4 Damage or failure when installation operation and maintenance instructions provided ar...

Page 3: ...t connecting tubing and the compressor will be covered free of charge if defective in material or workmanship 3 If this appliance is ever used for other than private family residential purposes this warranty only applies for 30 days from the date of purchase Service Type Kenmore window and portable air conditioner units are serviced on a carry in basis whereby customer brings the unit to a Sears R...

Page 4: ...ars at 1 800 4 MY HOME Prevent Accidents To reduce the risk of fire electrical shock or injury to persons when using your air conditioner follow basic precautions including the following If the air conditioner is to be installed in a window you will probably want to clean both sides of the glass first If the window is a triple track type with a screen panel included remove the screen completely be...

Page 5: ...tery in tray with POSITIVE side facing UP according to diagram Re insert battery tray TO REPLACE BATTERY Battery Size CR2025 ACTIVATES TIMER SLEEP MODE FILTER RESET BUTTON TURNS UNIT ON OR OFF ADJUSTS TEMPERATURE OR TIME SETS FAN SPEEDS DISPLAYS TEMPERATURE TIME SETS MODE REMOTE CONTROL ON OFF ADJUSTS TEMP TIME AUTO FAN SLEEP MODE SETS FAN SPEEDS ACTIVATES TIMER INFRARED REMOTE WINDOW TAB CAUTION ...

Page 6: ...t will automatically go to the highest speed The fan speed will re adjust back to the slowest speed as the room returns to the original set temperature To operate on Fan Only press the MODE button to select Use Fan Only function to circulate room air without air conditioner cooling You can use any fan speed you prefer and the actual room temperature will be displayed in the DISPLAY To use Cool pre...

Page 7: ... will save energy usage in this mode The compressor and motor will turn off once the room is at the desired temperature The air will be sampled for 20 seconds every 10 minutes until the room is above the set temperature at which point the compressor turns back on and the fan runs The entire process is now repeated Press the UP and DOWN arrows to select the desired time up to 24 hrs The control wil...

Page 8: ...h a key hole overflow drain hole can use drain kit 5304481680 to connect a 1 2 inch drain hose for safe disposal of excess system water This part can be ordered at www SearsPartsDirect com There is a 2 Second delay for the compressor shutting down when selecting FAN ONLY This is to cover the possibility of having to roll through to select another mode FRESH AIR VENT CONTROL On 253 35310 253 35312 ...

Page 9: ...ughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation...

Page 10: ...E AIR CONDITIONER TURNS ON AND OFF BY ITSELF Check if Then Outside temperature is extremely hot Set fan speed at the fastest setting for maximum cooling Page 6 Timer turned unit ON or shut unit OFF Push ON OFF Button to turn unit ON or OFF Page 6 THE AIR CONDITIONER DOES NOT COOL THE ROOM ICE BEHIND FRONT PANEL Check if Then Outside temperature is below 16 C Set mode to FAN ONLY and fan speed to f...

Page 11: ...gerant passing through evaporation Page 11 Gurgling or hissing sounds Beeping Electronic Control Normal noise when electronic control settings are changed Vibration Unit Vibration Due to poor wall or window construction or incorrect installation Page 11 Room Air Conditioner Troubleshooting Guide Normal Sounds High Pitched Whine Today s high efficiency compressors may have a high pitched whine duri...