146.22124910 • 7
Hold coupling nut and regulator
as shown for proper connection
to LP tank valve
.
Leak Testing Valves, Hose and Regulator
1. Turn all grill control knobs to OFF.
2. Be sure regulator is tightly connected to LP tank.
3. Completely open LP tank valve by turning OPD hand
wheel counterclockwise. If you hear a rushing sound, turn
gas off immediately. There is a major leak at the
connection. Correct before proceeding by calling Sears
for replacement parts at 1-844-553-6667.
4 .Brush soapy solution onto areas where bubbles are shown
in picture below:
6. Turn the coupling nut clockwise and tighten to a full stop. The
regulator will seal on the back-check feature in the LP tank valve,
resulting in some resistance. An additional one-half to three-quarters
turn is required to complete the connection. Tighten by hand only -
do not use tools.
NOTE:
If you cannot complete the connection, disconnect regulator and
repeat steps 5 and 6. If you are still unable to complete the connection,
do not use this regulator!
Call 1-844-553-6667 for an identical replacement part.
DANGER
• Do not insert any tool or foreign object into the valve
outlet or safety relief valve. You may damage the
valve and cause a leak. Leaking propane may result in
explosion, fire, severe personal injury, or death.
WARNING
• Outdoor gas appliance is not intended to be installed
in or on a boat.
• Outdoor gas appliance is not intended to be installed
in or on an RV.
• Never attempt to attach this grill to the self-contained
LP gas system of a camper trailer or motor home.
• Do not use grill until leak-tested.
• If a leak is detected at any time, STOP and call the
fire department.
• If you cannot stop a gas leak, immediately close
LP cylinder valve and call LP gas supplier or your fire
department!
▲
Never remove threaded
orifice at end of valve.
5. If “growing” bubbles appear, there is a leak. Close LP tank
valve immediately and retighten connections. If leaks
cannot be stopped do not try to repair. Call for
replacement parts at 1-844-553-6667.
6. Always close LP tank valve after performing leak test by
turning hand wheel clockwise.
Summary of Contents for 146.22124910
Page 1: ......
Page 4: ......
Page 15: ...146 22124910 15 BEFORE ASSEMBLY ...
Page 16: ...16 146 22124910 BEFORE ASSEMBLY ...
Page 32: ......
Page 34: ......
Page 45: ...146 22124910 45 ANTES DE MONTAJE ...