COMPONENT ACCESS
n
4-5
Ice Bin Components (cont.)
accEssiNg icE BiN ELEcTricaL cONNEcTiONs
8. Remove the water tube from the left side of the cover
and roll cover up and out. See
Figure 12
.
rEmOviNg rEsErvOir aNd pumps
10. Remove 1 hex head screw and remove the reservoir
assembly. Remove wire harness. See
Figure 14
.
FIGURE 12
9. Remove wire harnesses. See
Figure 13
.
NOTE:
If one of the pumps is not functioning during the
diagnostic check a resistance reading can be made.
Approximately 3.6 OHMS of resistance should be measured
across the recirculation pump and the drain pump.
If a pump checks good but did not operate during the
diagnostic test – make sure all the connections are tight
and retry the operation before replacing the pump.
FIGURE 13
FIGURE 14
11. Use a pair of pliers to remove christmas tree retainers.
See
Figure 15
.
FIGURE 15