SI-BM03
4 Functional Beauty Intrument
(Notice: The machine has auto protection to shut off the Galvanic
function when the output current reached excessive intensity to
the treatment area. To restart the function, turn the intensity knob
left to the off position, then turn right
to reactivate the function.)
6. To select the desired current, simply press the button on
the front panel as drawn on the machine.
Vac/Spary Function
4 Functions
- High Frequency
- Galvanic
- Vacuum
- Spray
Machine Structure
VAC&SPY Indicator Light
Galcanic Power
VAC&SPY Indicator Light
VAC&SPY Power
VAC&SPY Intensity
Ga/-Output
VAC Output
Galanic DOWN/UP
+/- Exchange
Galanic ON/OFF
H.F Intensity
High Frequency
Output
SPY Output
1. Start the machine: To turn on the machine, press the
Vac/Spray power switch.
2. Connect the hoses to the machine, black for suction
and white for spray.
3.Determine the choice of function and use the accessories
accordingly, Glass ventouses for suction and bottles for spray.
4. Depending on the function being used, disconnect the
opposite hose for best results.
5. To increase vacuum or spray, turn the intensity control to
the right and to decrease the vacuum or spray, turn
the control to the left.
6.When the machine is not in use make sure the power
switch is Off.
High Frequency Function
1. Connect the High Frequency handle's wire to the machine (it
only fits one way)making sure to fasten it into place the securing
ring.
2. Simply insert the desired glass electrode (metal end first) into
the hole at the end of the handle.
3. Using the power switch, turn the machine to the
“on”
position and the glass electrode should light up.
4. To control the intensity of the electrode, use the knob located
at the center of the face place labeled
“Min/Max”.
Turning this knob allows the user to adjust the current to
match the desired need.
5. When the machine is not in use, make sure the power
switch is in the
“Off” position.
Galvanic Function
1.Connect the Negative & positive (Red) wire into the machine
using the plug and fasten the securing ring to hold the plug in place.
2.Connect the Electrode handle to the end of the red wire.
3. Connect Black wire to the machine and connect the straight indifferent
electrode to the end of the Black wire for the client to hold.
4. Chose the electrode that best desired treatment and insert it into the
Electrode handle and tighten the secure head to prevent dropping the
electrode.
5. Select the current you wish to use,
“-“or “+”. Do not set the
intensity too high to start with.
Specifications:
Voltage:
110V/60HZ
220V/50HZ
Power: 50W
12
13