background image

www.kenall.com  |  P: 800-4-Kenall  |  F: 262-891-9701  |  10200 55th Street Kenosha, Wisconsin 53144, USA         

This product complies with the Buy American Act: manufactured in the United Stateswith more than 50% of the component cost of US origin It may be covered by patents 
found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co. 

4

INSTALLATION INSTRUCTIONS

HBM_F-4938_090418

1.  Remove screws and lift cover of fixture.  

Loop safety cable under center support.

2.  Send straight end through loop end of the  

safety cable.

3.  Replace cover and secure the cable to the  

super-structure.

II.  Safety Cable Option

LOOP HANGER

 

INSTALLATION – HL  

(ATTACHED AT FACTORY)

Aircraft cable (not included) is recommended for attaching the fixture structural to the upper structural. 

SAFETY RECOMMENDATION

1.

  Wire cord leads to power supply leads using 

connectors suitable for the gauge and number of 

wires being used. Black fixture lead connects to 

the supply conductor, white fixture lead connects 

to the neutral supply conductor, and the grounding 

wire must be connected to a suitable ground. 

2.

  Hang luminaire by attaching to user supplied chain 

or cables.

3.

   Connect power cord.

4. 

As a safety recommendation, an additional aircraft 

cable (not included) should be used to attach the 

loop hanger and supporting structure.

LOOP HANGER

CORD WITH  

QUICK-DISCONNECT

Reviews: