6.2 Technical data TX 135
Flexlite TX
135GF
Feature
Value
Type of cooling
Gas
Coolant flow rate (l/min)
l/min
-
Coolant pressure (min)
MPa
-
Coolant pressure (max)
-
Arc striking voltage
kV
10
Rating of electrical components (remote, nominal)
V
10
mA
10
Type of connection
Current-gas
R1/4
Control
7-pin
Coolant
-
Electrode diameters
mm
1.0…2.4
Load capacity @ 40 % (Argon)
A
130
Load capacity @ 100 % (Argon)
A
-
Operating temperature range (°C)
°C
-10…+40 °C
Storage temperature range
°C
-40…+60 °C
Minimum cooling power at 1.0 l/min
kW
-
Remote control
Optional
Neck type
Bendable
This equipment complies with standard IEC 60974-7.