FA Flow Control

Expected operating time of the blower unit after 
being fully charged (hours)

Airflow

Filter

min.

middle max.

P R SL

X

10 h

X

6 – 7 h

X

4 – 5 h

 

Note! Operating time can be decreased if the filters 

are clogged.

12.  Ordering codes

Delta 90 SFA welding FA Flow Control

9873310

Delta+ 90 XFA welding FA Flow Control

9873320

FA Flow Control unit with Li-ion battery

Complete package

W013560

Spare parts and consumables

FA Battery charger, Li-ion

W013564

FA Li-ion battery, 4.4 Ah

W007507

FA Flow Control Flexi hose

W007487

FA Flow Control Flow indicator

W007488

FA Comfort belt 

W007489

FA Basic filter

2 pcs, standard

W007490

FA Flow Control sealing ring

for filter

W007491

FA Flow Control pre-filter

10 pcs

W007492

FA FLow Control odour filter

10 pcs

W007494

FA Flow Control Filter cover

W013565

Optional

FA Flexi hose cover

W007788

FA Heavy duty comfort belt

W007789

FA Head cover

W007827

FA Protective neck cover

W007828

ENGLISH

Summary of Contents for FA Flow Control

Page 1: ...manual Brugsanvisning Gebrauchsanweisung Manual de instrucciones K ytt ohje Manuel d utilisation Manuale d uso Gebruiksaanwijzing Bruksanvisning Instrukcja obs ugi Manual de utiliza o Bruksanvisning F...

Page 2: ...Kemppi Oy 2019 1 2 10 3 5 1 s 7 8 1 2 4 1 s 9 3 6...

Page 3: ...ng on the current conditions must be followed Use only original filters certified for the particular respiratory system Note If the recommendations stated in this manual are ignored the warranty is au...

Page 4: ...goes into the red zone the air flow is insufficient and the filter s must be replaced 4 3 Using the FA Flow Control 1 Switch on the unit by pressing the ON OFF button on the control panel 2 The airflo...

Page 5: ...er back Ensure you snap the cover into place on both sides 7 Battery Note The battery must be charged before the first use The charger must not be used for any other purpose than that for which it was...

Page 6: ...the filter Battery is not charged properly Charge the battery If problem persists replace the battery Battery cannot be charged Battery contact is damaged Replace the battery Charger is faulty Contac...

Page 7: ...battery Complete package W013560 Spare parts and consumables FA Battery charger Li ion W013564 FA Li ion battery 4 4 Ah W007507 FA Flow Control Flexi hose W007487 FA Flow Control Flow indicator W0074...

Page 8: ...00 A 13 13 14 350 A 14 14 400 A 450 A 15 15 500 A 14 14 15 550 A 15 15 600 A Declarations of Conformity Overensstemmelseserkl ringer Konformit ts erkl rungen Declaraciones de conformidad Vaatimustenmu...

Reviews: