3.  Unpacking and assembly

3.1  Unpacking

Check that the package is complete and that no part has 
been damaged in transit or for other reasons.

A package with the complete system including 
accessories contains:

1.

Blower unit including battery

1 pc

2.

Belt

1 pc

3.

Flexi hose

1 pc

4.

Air flow indicator

1 pc 

5.

Battery charger

1 pc

6.

Operating manual

1 pc

The  FA Flow Control is supplied with P R SL filter.

3.2  Assembly

1.  Connect the battery to the blower unit.
2.  Attach the unit onto the belt. Make sure that the 

filter or filters are fitted properly.

3.  Connect the air hose to the blower unit.
4.  Connect the air hose to the headpiece and hand 

tighten. 

4.  Usage

4.1  Inspection before every use

Do the following checks always before you start using the 
equipment: 

•  Check that all components are in good condition 

with no visible damage. Replace any damaged or 
worn parts. Carefully examine the air hose, seals and 
the facepiece.

•  Check that there is a good connection between the 

air hose and the headpiece as well as the blower unit

•  Ensure that there is sufficient air flow as explained in 

section "Air flow test".

•  Check that the air is supplied through the whole 

respiratory system from the blower to the hood.

Fully charge the battery before first use. 

4.2  Air flow test

Before every use, you should conduct an air flow test on the 
equipment as follows:

1.  Disconnect the air hose from the blower unit.
2.  Connect the air flow indicator to the unit.
3.  Turn the unit on and check the air flow using the 

bottom air flow level.

If the pointer on the air flow indicator goes into the red 
zone, the air flow is insufficient and the filter(s) must be 
replaced.

4.3  Using the FA Flow Control

1

 Switch on the unit by pressing the ON/OFF button on 

the control panel. 

2

 The airflow can be adjusted with the plus and minus 

buttons (+ and –) from 170 l/min up to 240 l/min. The 
number of lit green LED diodes indicates the airflow level. 

The unit ensures a constant supply of air. The microprocessor 
inside the unit automatically regulates the motor speed to 
compensate the filter clogging and the battery state. 

If the microprocessor cannot maintain the adjusted airflow, 
an acoustic alarm signal can be heard and the LED diodes 
display RED in colour. If possible, the microprocessor 
automatically reduces the airflow to the next lower level. 

3

 When the airflow falls below the minimum level, the 

alarm intensifies. Then the user must stop working at once 
and change the filter or recharge/change the battery.

To check the alarm function, perform the air flow test as 
follows:

1.  Disconnect the air hose from the headpiece.
2.  Cover the disconnected end of the air hose with 

your hand. The blower starts to run faster after 
about 20 seconds, the audible alarm activates and 
the LED diodes on the control panel start blinking.

3.  Remove your hand . The blower speed should 

decrease.

If the blower speed does not change, it is necessary to 
check the unit.

4.4  Checking the battery state 

4

  Press and hold the left button (–) for more than 1 

second. The more red coloured LED diodes come on, the 
higher the remaining battery capacity is.

4.5  Checking the filter

5

 Press and hold the right button (+) for more than 1 

second. The more yellow LED diodes come on, the more 
clogged the filter is.

After releasing the buttons, the LED diodes return to the 
green light state indicating the current airflow.

Summary of Contents for FA Flow Control

Page 1: ...manual Brugsanvisning Gebrauchsanweisung Manual de instrucciones K ytt ohje Manuel d utilisation Manuale d uso Gebruiksaanwijzing Bruksanvisning Instrukcja obs ugi Manual de utiliza o Bruksanvisning F...

Page 2: ...Kemppi Oy 2019 1 2 10 3 5 1 s 7 8 1 2 4 1 s 9 3 6...

Page 3: ...ng on the current conditions must be followed Use only original filters certified for the particular respiratory system Note If the recommendations stated in this manual are ignored the warranty is au...

Page 4: ...goes into the red zone the air flow is insufficient and the filter s must be replaced 4 3 Using the FA Flow Control 1 Switch on the unit by pressing the ON OFF button on the control panel 2 The airflo...

Page 5: ...er back Ensure you snap the cover into place on both sides 7 Battery Note The battery must be charged before the first use The charger must not be used for any other purpose than that for which it was...

Page 6: ...the filter Battery is not charged properly Charge the battery If problem persists replace the battery Battery cannot be charged Battery contact is damaged Replace the battery Charger is faulty Contac...

Page 7: ...battery Complete package W013560 Spare parts and consumables FA Battery charger Li ion W013564 FA Li ion battery 4 4 Ah W007507 FA Flow Control Flexi hose W007487 FA Flow Control Flow indicator W0074...

Page 8: ...00 A 13 13 14 350 A 14 14 400 A 450 A 15 15 500 A 14 14 15 550 A 15 15 600 A Declarations of Conformity Overensstemmelseserkl ringer Konformit ts erkl rungen Declaraciones de conformidad Vaatimustenmu...