10. Troubleshooting
Fault
Probable reason
Recommendation
The blower unit does
not work at all.
Entirely discharged battery.
Verify if the blower unit works with
another charged battery.
Charge the battery.
If problem persists, replace the battery.
Faulty motor, circuit board or
connector.
Contact your supplier.
Low airflow.
Blocked air hose or airduct.
Check and remove blockage.
Leakage.
Check all seals, connectors and the air
hose. Make sure that air cannot leak
through holes or tears.
Battery is not sufficiently charged.
Charge the battery.
If problem persists, replace the battery.
Blocked Filter.
Change the filter.
Short operating time.
Clogged Filter.
Change the filter.
Battery is not charged properly.
Charge the battery.
If problem persists, replace the battery.
Battery cannot be
charged.
Battery contact is damaged.
Replace the battery.
Charger is faulty.
Contact your supplier.
Battery cannot be
charged sufficiently.
Battery is worn out.
Replace the battery.
11. Technical data
FA Flow Control
Airflow
140 – 210 l/min at 8 adjustable flow rates
Weight of the blower unit incl. the filter and battery
980 g
Noise level
< 70 dB
Battery lifetime
Max. 500 charging cycles
Charging time
4 – 5 hours
Belt size
Max. 150 cm
Recommended temperature range
10 – 40 °C
Recommended humidity range
20 – 80 % Rh
Certification
EN 12941/A2 TH2 P R SL
Manufacturer (manufactured for Kemppi by)
CleanAir Ltd.
Notified body for CE testing:
Výzkumný ústav bezpečnosti práce, v.v.i. – ZL
Testing Laboratory No. 1024
Jeruzalémská 9, 116 52 Praha 1
Authorized Body 235
Notified Body 1024