6.1 Ambient conditions
This section describes suitable ambient conditions for the Robot Gun Cleaning Station.
Table 1: Ambient conditions
Ambient temperature
5 °C to 50 °C
Transport and storage
-10 °C to 55 °C
Relative humidity
up to 90% at 20 °C
6.2 Weight and dimensions
This section describes the Robot Gun Cleaning Station unit’s weight and dimensions.
Table 2: Weight and dimensions
Weight
approx. 30 kg
approx. 22.3 kg
Dimensions
approx.
255 mm × 337 mm × 1052 mm
Approx.
255 mm × 337 mm × 477 mm
6.3 The pneumatic distributor block
This section describes the Robot Gun Cleaning Station’s pneumatic distributor block.
Table 3: Pneumatic distributor block
Compressed air connection
G1/4"
Internal width
min. Ø 6 mm
Nominal pressure
6 bar
Working pressure
6–8 bar
Quality of compressed air (ISO 8573-1:2010)
min. class 4
6.4 The electrical clamping block
This section describes the Robot Gun Cleaning Station’s electrical clamping block.
Table 4: Electrical clamping block
Operating voltage / internal operating voltage
24 V DC / 200 mA
Protection class
IP21
3 inputs of the 5/2 directional valves
Activation
24 V DC
Power consumption per valve
2 outputs of the inductive proximity switch (normally
open switch) (PNP ≠ positive switching / NPN ≠ negative
switching)*
10–30 V DC
Operating voltage
10–30 V DC
Current consumption
approx. 4 mA (24 V)
Allowed residual ripple
Vss < 10%
Permanent current per proximity switch
max. 100 mA
Voltage drop
approx. 1.5 V (200 mA)