13
Robot Gun Cleaning Station
© Kemppi Oy 2016
1616
OPERA
TING M
ANU
AL
10. INSTALLING THE ROBOT GUN
CLEANING STATION
This section describes how to install the Robot Gun
Cleaning Station unit.
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing,
unmounting, and repair work, the following instructions
must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Pull the power plug.
The parts of the system are depicted in the figure below.
Proceed as follows:
1. Connect the two hoses (4 and 8) to the applicable
bottles to put the injection unit of the welding
torch into operation.
All other connections for compressed air are pre-mounted
at the factory.
Ensure that the non-return valve (6) is attached to the
suction hose (4).
2. Connect the device through the compressed-air
hose.
Figure 7: Installing the Robot Gun Cleaning Station
1. Return connection (pre-mounted)
2. Setting for the amount of suction air
3. Connection of anti-spatter system to injection unit
4. Suction hose
5. Anti-spatter bottle (full)
6. Non-return valve
7. Anti-spatter drain bottle
8. Hose
9. Compressed-air connection (pre-mounted)
10. Suction connection (pre-mounted)