11
A5 MIG Rail System
© Kemppi Oy 2021
R01
OPERA
TING M
ANU
AL
3.2.3 Setup menu A
P1 CH off
<8> 45
6mm
Long press of the MENU button activates Setup menu A,
which contains 3 options:
• CH remote
• WF+V fac
• Delay car
Brief press of the MENU button toggles the menu items.
No buttons pressed in 3 seconds or a new long press on
MENU button exits the Setup Menu A.
CH remote
A
CH off
CH remote: 0
Use + and – buttons to set the remote memory channels
function on or off:
• If CH setting is OFF, the selected P setting only
enables the corresponding carriage program
(P1, P2 etc.).
• If CH setting is ON, the selected P setting also
activates the corresponding memory channel at
the wire feeder (CH1, CH2 etc.).
To use the wire feeder’s memory channels, the CH
REMOTE setting must be ON at the wire feeder. In this
case, the fine tuning is disabled at the carriage remote
control unit.
WF+V fac
A
CH off
WF 0
V 0
Set the factor that is used for determining the roughness
of fine tuning and affects the adjustment of WFS and arc
voltage:
1. Use + button to select value 0, 1, 2, 3 or 4
(default = 2).
• Higher setting = wider steps
• Lower setting = narrower steps
2. Press MENU to continue.
The wire feeder scale varies according to the min/
max limits set in the power source. If the power source
holds narrow limits, the carriage may require a rough
scale. If limits have not been set in the power source,
the carriage requires a finer scale. Different applications
may benefit from different scaling.