Installation instructions
2. Insert the piping-hole sleeve into the hole to prevent the
connection piping and wiring from being damaged when
passing through the hole.
Ø
Ø
55/ 65
Indoor
Outdoor
Wall pipe
Seal pad
Installation of Drain Hose
1. Connect the drain hose to the outlet pipe of the
indoor unit. Bind the joint with binding tape.
drain hose
outlet pipe of
indoor unit
outlet pipe of
indoor unit
binding tape
2. Put the drain hose into insulating tube.
insulating tube
drain hose
outlet pipe of
indoor unit
binding tape
3. Wrap the insulating tube with wide binding tape to prevent the
shift of insulating tube. Slant the drain hose downward slightly
for smooth drainage of condensing water.
outlet pipe of
indoor unit
insulating tube
connected
binding tape
NOTE: The insulating tube should be connected reliably with the
sleeve outside the outlet pipe. The drain hose should be slanted
downward slightly, without distortion, bulge or fluctuation. Do not
put the outlet in the water.
Installation of indoor unit
Installation of Mounting Plate
1. The mounting plate should be installed horizontally.
As the water tray's outlet for the indoor unit is two-way type,
during installation, the indoor unit should slightly slant to water
tray's outlet for smooth drainage of condenser water.
2. Fix the mounting plate on the wall with screws.
3. Be sure that the mounting plate has been fixed firmly enough
to withstand about 60kg. Meanwhile, the weight should be
evenly shared by every screw.
2.5kW and 3.5kW UNITS:
Ø55
Ø55
34.5
316
160
35
80
Above 150mm
from the ceiling
159
1048
346
70
70
70
39
83
90
55
130
81
90
55
94
166
281
575
158
685
205
70
5.2kW UNIT:
Ø55
Ø55
34.5
316
160
35
80
Above 150mm
from the ceiling
159
1048
346
70
70
70
39
83
90
55
130
81
90
55
94
166
281
575
158
685
205
70
7.0 kW and 8.0 kW UNITS:
Ø55
Ø55
34.5
316
160
35
80
Above 150mm
from the ceiling
159
1048
346
70
70
70
39
83
90
55
130
81
90
55
94
166
281
575
158
685
205
70
Drill Piping Hole
1. Slant the piping hole on the wall slightly downward to the
outdoor side.
Piping hole
Units
( 55)
2.5 kW, 3.5 kW
( 70)
5.2kW, 7.0 kW and 8.0 kW
bulge
distortion
Flooded