Safety

WARNING

caution

 The unit must only be installed by a qualified refrigeration 
mechanic and electrical work carried out by a qualified 
electrician according to AS/NZS3000 electrical installation 
standard and all local and national regulations, and in 
compliance with this manual.

 Before installation, please contact a qualified air conditioner 
installer. If the unit is not installed by a qaulified air conditioner 
installer, any resulting malfunction may not be covered by 
warranty.

 If the supply cord is damaged, it must be replaced by the 
manufacturer, its service agent or similarly qualified persons in 
order to avoid a hazard.

 The appliance must be positioned so that the plug or isolation 
switch is accessible.

 The temperature of refrigerant circuit will be high, please keep 
the electrical cable away from the copper tube.

  This appliance is not intended for use by persons (including 
children) with reduced physical, sensory or mental 
capabilities,or lack of experience and knowledge, unless they 
have been given supervision or instruction concerning use of 
the appliance by a person responsible for their safety.

 Children should be supervised to ensure that they do not play 
with the appliance.

WARNING

warning

Before obtaining access to terminals, all supply circuits must be 

disconnected.

Please read this installation manual and the user manual before 
installation and carefully store in a handy place for later reference. 
Inside you will find many helpful hints on how to install and test the 
air conditioner properly. 

Electrical work must be installed by a licensed electrician. Be sure 
to use the correct rating of the power plug and main circuit for the 
model to be installed.

Incorrect installation due to ignoring this instruction may cause 
harm or damage, which may not be covered under warranty.

Meanings of symbols used in this manual are shown below:

WARNING

warning

This symbol indicates information concerning your  

personal safety

WARNING

caution

This symbol indicates information on how to avoid damaging the 

appliance

TIPS & INFORMATION

 important

This symbol indicates tips and information about  

use of the appliance

ENVIRONMENTAL TIPS

 environment

This symbol indicates tips and information about economical and 

ecological use of the appliance

 This symbol indicates never to do this

 This symbol indicates always do this

Important safety instructions

Notice for installation

Summary of Contents for KSV80HRD

Page 1: ...Inverter Split Room Air Conditioner Installation Manual KSV25HRD KSV35HRD KSV52HRD KSV70HRD KSV80HRD Refrigerant R410A...

Page 2: ...our local Electrolux Customer Care Centre ENVIRONMENTAL TIPS environment Information on disposal for users Most of the packing materials are recyclable Please dispose of those materials through your l...

Page 3: ...esponsible for their safety 7 Children should be supervised to ensure that they do not play with the appliance WARNING warning Before obtaining access to terminals all supply circuits must be disconne...

Page 4: ...nt welders or medical equipment salt laden air prevails such as close to coastal areas the air is contaminated with industrial vapours and oils the air contains sulphurous gas such as in hot spring zo...

Page 5: ...adhered to the air conditioner will not perform to specification may not be able to be serviced and the warranty may be voided The installation must allow for reasonable access by a service technician...

Page 6: ...he outlet in the water Installation of indoor unit Installation of Mounting Plate 1 The mounting plate should be installed horizontally As the water tray s outlet for the indoor unit is two way type d...

Page 7: ...of indoor unit cut off the tailings from the chassis when necessary As shown in Fig 1 a Cut off the tailings 1 when routing the wiring only b Cut off the tailings 1 and tailings 2 when routing both th...

Page 8: ...Remove flare nuts attached to indoor and outdoor unit then put them on pipe tube having completed burr removal Note It is not possible to put them on after flaring work Flare nut Copper tube D Flarin...

Page 9: ...age Test 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open t...

Page 10: ...accurate Operation Test 1 Before Operation Test a Do not switch on power before installation is finished completely b Electric wiring must be connected correctly and securely c Cut off valves of the...

Page 11: ...own in the fig For 5 2kW is as below Clasp of RJ45 plug of network cable shall aim at the notch of RJ45 terminal to be installed The clasp shall be towards inside as shown in the fig For 7 0kW and 8 0...

Page 12: ...12 Notes Notes...

Page 13: ...13 Notes Notes...

Page 14: ...14 Notes Notes...

Page 15: ...t claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse i...

Page 16: ...ator com au NEW ZEALAND phone 0800 436 245 fax 0800 225 088 email customercare electrolux co nz web kelvinator co nz For more information on all Kelvinator appliances or for dimension and installation...

Reviews: