Kelvinator Air Conditioning
operating the air conditioner 13
12 operating the air conditioner
Kelvinator Air Conditioning
Note: The time of the CLOCK must be set before the AUTO-
TIMER feature can operate. The CLOCK time can not
be adjusted after setting the AUTO-ON/OFF timer.
Press the CLOCK/TIMER button on the remote control
for about 3 seconds, the previous time displays and
starts to flash.
* Clock accuracy is within 15 seconds per day.
To set the new time, follow 1 and 2 of "Initial Setting of
the Clock".
caution
Static electricity or other factors (in case of extremely high
voltage) can cause the remote control clock to re-initialise.
If your remote control is initialised (flashing "12:00"), readjust
the clock before you start operation.
Specification
Model
RG03A/BGEF-ELBR, RG03A/BGCEF-ELBR
Rated Voltage
3.0V(Alkaline dry batteries Lr03 2)
Transmission
Distance
8m (when voltage becomes lower, the
transmission distance will be reduced.)
Environment
-5 C 60 C(-41OF~140OF)
Digital display button function
Auto
Def.
Timer
Frequency
Auto
Def.
Timer
Frequency
When you press the DIGITAL button, the setting temperature
display on indoor unit will be shut off.
Press the button again and the display will be activated.
This function is useful when you want to shut down the
display when you are sleeping.
Setting the clock
Before you start operating the air conditioner, set the clock
of the remote control using the procedures given in this
section. The clock panel on the remote control will display
the time regardless of whether the air conditioner is in use
or not.
Initial Setting of the Clock
After batteries are inserted in the remote control, the clock
panel will display "12:00" and begin to flash.
1 TEMP/TIME adjust button
• Press this button to set the time.
Forward.
Backward.
• Each time you press the button, the time moves forward
or backward by one minute depending on which side
you press.
• The time alters as quickly as you push the button.
• Keep pressing the button without releasing, the time
moves forward or backward by 10 minutes depending on
which side you press.
When the right time is achieved, press the CLOCK/TIMER
button to confirm or release the button and wait for 3
seconds, the clock time stops flashing and the clock
starts operating.
Clock/Timer button
When the right time is set, press the CLOCK/TIMER button to
confirm or release the
1
2
3
4
5
6
7
8
9
10
8
11
AUTO
MODE
❄
or
1
2
3
4
5
6
7
8
9
10
8
11
AUTO
MODE
❄
and wait for 3 seconds, the
clock time stops flashing and the clock starts operating.
TIMER ON
TIMER OFF
(Off
Start
Stop operation)
This feature is useful when you want to start the air
conditioner before you wake up and stop it after you leave
the house.
Example:
To start the air conditioner at 6:00 the next morning, and
stop it at 8:00.
1 Press the CLOCK/TIMER button, the TIMER ON indicator
illuminates and the set time flashes.
2 Use the TEMP/TIME button to display "6:00" besides the
TIMER ON display of the remote control.
3 Press the CLOCK/TIMER button again to activate the
TIMER OFF feature.
4 Use the TEMP/TIME button to display "8:00" besides the
TIMER OFF display.
5 Wait for 3 seconds and the setting time stops flashing
and this function is activated. The screen will revert back
to displaying the clock time.
Off
Stop
Start
6:00
8:00
Notes: The timer setting (TIMER ON or TIMER OFF) that in
sequence occurs directly after the actual time will be
activated first.
caution
1 When replacing batteries, do not use old batteries or
different types of batteries. Otherwise it may cause the
remote control to malfunction.
2 Remove the batteries when not being used for a long
time. Otherwise, battery leakage may damage the
remote control.
3 To prevent damage, please do not drop the remote
control.
4 The average battery life during normal use is
approximately 5 months.
The actual battery life is based on operation conditions.
Replace the batteries when there is no receiving beep
from the indoor unit or if all the indicators are shown on
the LCD window during operation.
5 Be sure there are no barriers between the remote control
and the receiver of the indoor unit otherwise the air
conditioner will not work.
6 Keep the Remote Control away from all liquids.
7 Protect the Remote Control from high temperatures and
exposure to radiation.
8 Keep the indoor receiver out of direct sunlight or the Air
Conditioner may malfunction.
9 Keep remote control away from EMI (Electro-Magnetic
Interference) generated by other household appliances.
Example:
To start the air conditioner at 6:00 a.m.
1 Press the CLOCK/TIMER button, the TIMER ON indicator
illuminates and the setting time flashes (if the displayed
time is just 6:00, 3 seconds later, the TIMER ON function
will be activated automatically).
2 Use the TEMP/TIME button to display"6:00" on the
TIMER ON display of the remote control.
3 Wait for 3 seconds and the setting time stops flashing
and this function is activated. The screen reverts back to
displaying the clock time.
Stop
On
23:00
Combined timer
(Setting both ON and OFF timers simultaneously)
TIMER OFF
TIMER ON
(On
Stop
Start operation)
This feature is useful when you want to stop the air
conditioner after you go to bed, and start it again in the
morning when you wake up or when you return home.
Example:
Now it is 20:00 hours in the evening. You want to stop the air
conditioner at 23:00 and start it again the next morning
at 6:00.
1 Press the CLOCK/TIMER button until the TIMER OFF
indicator displays and time setting flashes.
2 Use the TEMP/TIME button to display "23:00" besides
the TIMER OFF display.
3 Press the CLOCK/TIMER button again to display the
TIMER ON indicator .
4 Use the TEMP/TIME button to display "6:00" besides
the TIMER ON display.
5 Wait for 3 seconds and the setting time stops flashing
and this function is activated. The screen will revert back
to displaying the clock time.
On
Stop
23:00
6:00
Start
1
2
3
4
5
6
7
8
9
10
8
11
AUTO
MODE
❄
MODE
❄
1
2