background image

Kelvinator Air Conditioning 

 operating the air conditioner  11

10  operating the air conditioner  

Kelvinator Air Conditioning

Timer operation

1  CLOCK/TIMER button
 

 Press the CLOCK/TIMER button, the current timer 
setting is displayed alongside either the TIMER ON 
or TIMER OFF indicator, and will flash.

2  TEMP/TIME button
 

Press to set the desired time.

   Forward
   Backward
 

 Each time you push the button, the time moves forward 
or backward by 10 minutes depending on which 
direction you press. The time alters as quickly as you 
press the button.

3   After setting the timer for TIMER ON and TIMER OFF, 

check that the TIMER indicator on the display panel of 
the indoor unit is illuminated.

4  Cancel button (CANCEL)
 

 Press the CANCEL button to cancel the timer setting.  
Preform steps 1, 2 and 3 to change the settings.

caution

When you select the timer operation, the remote control 
automatically transmits the timer signal to the indoor unit at 
the specified time.
Therefore, keep the remote control in a location from which it 
can transmit the signal to the indoor unit properly.
The effective operation time set by remote control is limited 
within 24 hours.

Examples of timer settings

Start

Off

6:00

Timer On

The TIMER ON feature is useful when you want the unit 
to turn on automatically before you return home. The air 
conditioner will automatically start operating at the set time.

IMPORTANT:  The time will be registered within a 0.5 

second period (after pressing the TEMP/TIME 
button), so you should continue pressing the 
button until the desired time is established. 
Otherwise you must repeat the steps again.

Drying operation

Start

Ensure unit is plugged in and power is available.
The OPERATION indicator on the display panel of the indoor 
unit starts flashing.
1  Mode select button (MODE)
 

Press to select DRY.

2  TEMP/TIME button
 

 Push the "TEMP/TIME" button to set the desired 
temperature.

3  ON/OFF button

Stop

When the remote control is off, push this button to start the 
air conditioner.
ON/OFF button
Push this button again to stop the air conditioner.

Note:  The fan speed cannot be adjusted when the unit is in 

AUTO and DRY mode.

MODE

1

2

3

4

•   The fan speed will be automatically controlled under 

dry operation.

•   During the dry operation, if the room temperature is 

lower than 10

O

C, the compressor stops operating and 

restarts only when the room temperature is above 12

O

C.

Eco operation

When you push the ECO button on the remote control 
during cooling, heating, or AUTO operation ,the air 
conditioner will automatically increase (cooling) or decrease 
(heating) the set temperature by 1

O

C per hour for the first two 

hours, then hold steady for the next 5 hours, after that the 
unit will stop operation. The fan speed will be automatically 
controlled. This feature can maintain the most comfortable 
temperature and save more energy for you.

AUTO operation

The air conditioner will control room temperature 
automatically around the temperature point set by you.
If the AUTO mode is uncomfortable, you can select desired 
conditions manually.

Cooling/Heating/Fan only operation

Start

Ensure unit is plugged in and power is available.
The OPERATION lamp on the display panel of the indoor unit 
starts flashing.
1   Mode select button (MODE) Press to select COOL, 

HEAT (Not applicable to cooling only models), 
or FAN ONLY.

2  TEMP/TIME button
 

 Set the desired temperature, the most comfortable 
temperature is between 21

O

C/70

O

F to 28

O

C/84

O

F.

3  Fan speed button
 

Press to select "AUTO" "LOW", "MED" and "HIGH"

4   ON/OFF button
 

 When the remote control is off, push this button to start 
the air conditioner.

Stop

ON/OFF button
Push this button again to stop the air conditioner.
The FAN ONLY mode does not control temperature.
Therefore, perform only steps 1,3, and 4 to activate 
this mode.

•   Open angle of the horizontal louver should not be 

set too small, as COOLING or HEATING performance 
may be impaired due to a restricted air flow area.

•   Do not operate unit with horizontal louver in 

closed position.

•   When the air conditioner is connected to power 

(initial power), the horizontal louver may generate a 
sound for 10 seconds, this is a normal operation.

How to operate the air conditioner
Automatic operation

When you set the air conditioner to AUTO mode, it will 
automatically select cooling, heating (only for reverse 
cycle models), or fan only operation depending on what 
temperature you have selected and the room temperature.
Once you select the operating mode, the operating 
conditions are saved in the unit's microcomputer memory.
Thereafter, the air conditioner will start operating under 
the same conditions when you simply push the ON/OFF
button on the remote control.

Start

Ensure the unit is plugged in and power is available. 
The OPERATION indicator on the display panel of the 
indoor unit starts flashing.
1   Mode select button (MODE) 

Press to select AUTO.

2  TEMP/TIME button 
 

Set the desired temperature. Normally,

 

set it between 21

O

C/70

O

F to 28

O

C/84

O

F.

3  ON/OFF button
 

 When the remote control is off, push this button to start  
the air conditioner.

Stop

ON/OFF button
Push this button again to stop the air conditioner.
If the AUTO mode is uncomfortable, you can select the 
desired conditions manually.
When you select the AUTO mode, you do not have to set the 
fan speed. The fan speed will be automatically controlled.

MODE

1

2

3

4

MODE

1

2

3

4

1 hour

1 hour

1 hour

1 hour

Set 

Temperature

Set 

Temperature

1

1

Eco  operation

1

1

Eco  operation

7 hours timer off

7 hours timer off

1

2
3

4
5
6

7

8

9

10

8

11

AUTO

MODE

Summary of Contents for KSV26HRB

Page 1: ...Inverter Split type Room Air Conditioner User Manual KSV26HRB KSV35HRB KSV53HRB KSV62HRB KSV70HRB KSV80HRB Refrigerant R410A ...

Page 2: ...authorised installer for installation of this unit Contact an authorised service technician for repair or maintenance of this unit If the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring Standards by authorised personnel only Conditions of use This appliance is intended to be use...

Page 3: ...oduct colour or scratching of its surface Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure If bracket is damaged there is concern of damage due to falling of unit Always insert the filters securely Clean filter once every two weeks Operation without filters may cause failure Do not place heavy object on the power cord and take care so that the ...

Page 4: ...g the manual control button until the unit is off 1 Open and lift the front panel up to an angle until it remains fixed with a clicking sound 2 One press of the manual control button will lead to the forced AUTO operation If you press the button twice within five seconds the unit will operate under forced COOL operation 3 Close the panel firmly to its original position caution It is recommended no...

Page 5: ...his function can only be used on COOL and HEAT mode and maintain the most comfortable temperature for you NOTE While the unit is running under Economic operation mode it will be cancelled when changing the mode or the fan speed Indicators on remote control Note All items shown in the figures are for explanation purpose only During the actual operation only the relative functional items are shown o...

Page 6: ...t 5 hours after that the unit will stop operation The fan speed will be automatically controlled This feature can maintain the most comfortable temperature and save more energy for you AUTO operation The air conditioner will control room temperature automatically around the temperature point set by you If the AUTO mode is uncomfortable you can select desired conditions manually Cooling Heating Fan...

Page 7: ...e flashes 2 Use the TEMP TIME button to display 6 00 besides the TIMER ON display of the remote control 3 Press the CLOCK TIMER button again to activate the TIMER OFF feature 4 Use the TEMP TIME button to display 8 00 besides the TIMER OFF display 5 Wait for 3 seconds and the setting time stops flashing and this function is activated The screen will revert back to displaying the clock time Off Sto...

Page 8: ...tteries still OK Replace if necessary 3 Have the batteries been inserted correctly Check that the and terminals are in the correct positions Cleaning the air filter NOTE Supply power must be disconnected before cleaning the indoor unit A clogged air filter reduces the cooling efficiency of this unit Please clean the filter every month or more often if necessary 1 Lift the indoor unit front panel u...

Page 9: ... heard due to louver restoring to its original position when power is first turned on 4 Dust is blown out from the indoor unit This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit 5 A peculiar smell comes out from the indoor unit This is caused by the indoor unit circulating smells permeated from building material from furniture or s...

Page 10: ...rchase is required before you can make a claim under this warranty 7 You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and t...

Page 11: ...rmation about Kelvinator appliances please visit your retailer phone or email our Customer Care team or visit our website telephone 1300 363 640 fax 1800 350 067 email customercare electrolux com au web www kelvinator com au Kelvinator We are part of the Electrolux family Share more of our thinking at www electrolux com au ...

Reviews: