4 heat pump specifications
Kelvinator heat pump hot water system
Heat pump specifications
KSE362HPCA Heat pump
Dimensions ( w x h x d) in mm
790 x 765 x 275
Heating capacity (kW)
Condition 1*
4.30
Standard power (kW)
1.25
Heating capacity (kW)
Condition 2*
4.70
Standard power (kW)
1.39
Heat pump circuit power rating (kW)
1.95
Maximum power rating including tank element operation (kW)
3.60
Power supply
220V-240V ~ 50 Hz
Refrigerant
R410A (1200g)
Maximum water pressure (kPa)
850
Outdoor protection rating
IP24
Circulating water inlet and outlet connections (mm)
20 (3/4")
Air side heat
exchanger
Fan motor power (kW)
0.08
Air outflow mode
Air flow from rear
Net weight (kg)
62
Full weight (kg)
65
NOTE: Condition 1*: Outdoor ambient temperature is
DB/WB 7°C/ 6°C, water inlet temperature of the units is 30°C ,
water outlet temperature is 35°C.
For more specific heat pump dimensions and safe installation
distances refer to page 8 of this manual.
Condition 2*: Outdoor ambient temperature is DB/WB 20°C/
15°C, water inlet temperature of the units is 15°C , water outlet
temperature is 55°C.
auxiliary heater boost button
air bleed valve
circulating water outlet
power cable entry
air outlet mesh enclosure
circulating water inlet