background image

7

between 1 - 1.2m long. The hose should not be subjected to abrasion, kinking or permanent deformation and 
should be able to be inspected along its entire length. Unions compatible with the hose fittings must be used 
and  connections  tested  for  gas  leaks.

  .The  fixed  consumer  piping  outlet  should  be  at  approximately  the  same 

height  as  the  cooker  connection  point,  pointing  downwards  and  approximately  150mm  to  the  side  of  the 
cooker. The hose should be clear of the floor when the cooker is in the installed position. Fix one end of the 
chain on the screw next to the gas inlet connection and the other end should be anchored to the floor/wall so 
that the chain prevents strain on the hose connections when he cooker is pulled forward. 
The  appliance  is  factory  set  for  Natural  gas.  The  test  point  pressure  should  be  adjusted  to 

  with  the 

Wok burner operating at maximum. 
The  appliance  is  set  up  to  operate  with  the  gas  specified  on  the  gas  type  label  placed  on  the  back  of  the 
appliance. 

To perform these operations the qualified installer will follow the indications given in the "Adaptation to the 
various types of gas" section. For safer operation make sure that the supply pressure respects the values given 
in the "Table of burner and injector characteristics". 
If installing for use with 

gas, ensure a gas regulator suitable for a supply pressure of 

 is part of the 

gas tank supply and the test point pressure is adjusted to 

Once the appliance has been installed, make sure that the gas pipe is neither squashed or damaged by moving 
parts. 

Before  Leaving  -  Check  all  connections  for  gas  leaks  with  soap  and  water.  DO  NOT  use  a  naked  flame  for 
detecting leaks. Ignite all burners both individually and separately to ensure correct operation of gas valves, 
burners  and  ignition. Turn  gas  taps  to  low  flame  position  and  observe  stability  of  the  flame  for  each  burner 
individually  and  separately. When  satisfied  with  the operation  of  the cooker, please instruct the user on  the 
correct method of operation. In case the appliance fails to operate correctly after all checks have been carried 
out, refer to the authorised service provider in your area. 

Adaptation to different types of gas 

To adapt the appliance to a gas different from that 
for which it was set up (see gas type label inside 
the warming compartment door) proceed as follows: 

remove the grids 
remove the burners caps and burner heads 
with a 7 mm socket spanner unscrew and remove the injectors. 
replace the injectors with those supplied corresponding to the 

       gas available (see burner and injector characteristics Table) 

replace the various parts proceeding in reverse. 

 When converting from Natural Gas to 

 ensure that theNG regulator is removed and replaced with the Test 

Point Assembly. A gas regulator suitable for a supply pressure of  should be part of the gas tank supply and the 
test point pressure should be adjusted to 

 

Setting the minimum flame 
The flame on the small output is regulated by the factory. 
When the injectors have been replaced or there are special
mains pressure conditions, it may be necessary to regulate 
the minimum flame again. The operations necessary to set
the minimum flame are as following: 

light the burner ;
turn the knob to the minimum position ;
take out the knob (and gasket if there is one) ;

The  flexible  tube  shall  be  fitted  in  such  a  way  that  it  cannot  come  into 

contact  with  a  moveable  part  of  the  housing  unit  (e.g.  a  drawer)and  does  not  pass  through  any  space 
susceptible  of  becoming  congested

20mbar

LPG 

29mbar

29mbar

When converting from Universal LPG to Natural Gas ensure that the LPG test point is removed and replaced
with the CE Approved NG Regulator supplied in this kit. The test point pressure must be adjusted to 
20mbar with the largest burner operating on maximum flame.

When converting from Natural Gas  to Universal LPG  ensure that the NG regulator is removed and replaced
with the Test Point Assembly supplied in this kit. An CE Approved gas regulator suitablefor a supply pressure 
of 29mbar should be part of the gas tank supply and the test point pressure must be adjusted to 29mbar. 

LPG

the pressure according to the data plate.

l
l
l
l

l

l
l
l

Summary of Contents for KC9650BL

Page 1: ......

Page 2: ...will enhance your kitchen such as cooker hoods built in hobs built in ceramic hobs and built in ovens microwaves washing machines tumble dryers dishwashers and refrigerators We make every effort to ensure that our products meet all your requirements Our service department is at your disposal to answer all your questions and to listen to your suggestions Please take not of the warranty section at t...

Page 3: ...ypes of gas pag 7 Setting the minimum flame pag 7 Burner and injector characteristic table pag 8 Instructions for use Description of the main parts of the appliance pag 8 Ignition and operation of the burners pag 9 Advice on the use of gas burners pag 9 Oven function pag 10 Electronic programmer pag 11 Maintenance and cleaning pag 14 CAUTIONS pag 12 Instructions for cooking 2 ...

Page 4: ...ee relevant section Before maintenance or cleaning disconnect the appliance from the mains and wait for it to cool down Do not use harsh abrasive cleaners or sharp metal scrapers to clean the oven door glass as they can scratch the surface which may result in the glass shattering When the burners are lit make sure that the flame is always regular Before removing the saucepan pot turn the burners o...

Page 5: ......

Page 6: ...U n R e g i s t e r e d ...

Page 7: ...llation and connection operations are carried out by qualified personnel complying with the local and general regulations in force Electrical features Oven light 25W Upper heating element 1950W Bottom heating element 1800W Grill heating element 2250W Circular heating element 1800W Ventilator motor 30W Cooling fan 11W This appliance shall be installed only by authorised persons and in accordance wi...

Page 8: ...ct method of operation In case the appliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area Adaptation to different types of gas To adapt the appliance to a gas different from that for which it was set up see gas type label inside the warming compartment door proceed as follows remove the grids remove the burners caps and bur...

Page 9: ... to the minimum position checking that the flame does not go out l for burners with safety valve make sure that the regulation obtained is sufficient to maintain heating of the thermocouple If it is not increase the minimum l 8 l l LPG TO NG Use a thin blade screwdriver to turn the by pass screw located above left of the gas valve shaft as shown right Turn gently the by pass screw clockwise to the...

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ...f enquiry before writing or telephoning When you contact us we need to know Your name Telephone Number Physical Address where appliance is located Model and Serial Number of the appliance Clear and concise details of the fault Customer Care For general enquiries or information regarding Kelvinator appliances contact Customer Care Department Kelvinator P O Box 3657 Johannesburg 2000 South African C...

Page 18: ... include bulbs loose glass glass oven doors enamelled surfaces discolouring of stainless steel surfaces filters and other parts subject to wear and tear 9 Kelvinator shall not be responsible in terms of this guarantee for the replacement or repair of any parts of the appliance if damaged during transit where packaging damage is visible 10 Repairs carried out under guarantee do not extend the guara...

Reviews: