Understanding Peak Positive Acceleration (PPA) Value
The sensor and the internal algorithm have been designed for measuring the Peak Positive Acceleration
(PPA) of the tibia. This value is obtained during the initial foot contact. The Z Axis is used for triggering
the detection but all axes are used in the calculation.
Treadmill & Pavement Running
Depending on the type of treadmill used, there may be an important variation in impact level between
treadmill and pavement running. In many cases, the treadmill running surface will absorb a significant
portion of the impact. The TgForce 3D sensor is initially set for normal pavement running. If the
recorded cadence is sometimes incorrect, you should adjust the sensor threshold (g) level (see
calibration section).