![Keithley KUSB-3116 Getting Started Manual Download Page 58](http://html1.mh-extra.com/html/keithley/kusb-3116/kusb-3116_getting-started-manual_3961350058.webp)
Chapter 4
44
Figure 18: Connecting Counter/Timer Signals to a Screw Terminal Panel for
an Event Counting Operation Using an External Gate
shows how to connect counter/timer signals either to your
own screw terminal panel to perform an event counting operation on
counter/timer 0 without using a gate. The counter counts the number
of rising edges that occur on the Counter 0 Clock input.
Figure 19: Connecting Counter/Timer Signals to a Screw Terminal Panel for
an Event Counting Operation Without Using a Gate
Signal
Source
Digital Ground
Counter 0 Clock
Digital Ground
External
Gating
Switch
8
28
31
Counter 0 Gate
Screw Terminal Panel
29
8
Signal Source
Counter 0 Clock
Digital Ground
18
Screw Terminal Panel
Summary of Contents for KUSB-3116
Page 10: ...Contents x...
Page 14: ...About this Manual xiv...
Page 15: ...1 1 Overview Hardware Features 2 Supported Software 4 Getting Started Procedure 5...
Page 20: ...Chapter 1 6...
Page 26: ...Chapter 2 12...
Page 64: ...Chapter 4 50...
Page 65: ...51 5 Verifying the Operation of a Module Overview 53 Running the Quick Data Acq Application 54...
Page 75: ...61 A Ground Power and Isolation Connections...
Page 78: ...Appendix A 64...
Page 82: ...Index 68...