1-10
Getting Started
Model 6485 and 6487 User’s Manual
HALT
Stops measurement process. Puts 6485 in idle state.
DIGITS
Use to set display resolution.
RATE
Use to select measurement rate.
and
Use to control cursor position for making selections or editing values.
SAVE
Use to save present setup to a memory location.
SETUP
Use to restore setup to either GPIB or factory defaults, or to a user memory location.
Also use to modify properties of power on defaults to either GPIB or factory defaults,
or to a user memory location.
STORE
Use to start buffer and modify the number of readings to store.
RECALL
Use to display stored readings (including maximum, minimum, peak-to-peak, aver-
age, and standard deviation). The
¹
and
ƒ
range keys scroll through the buffer and the
ß
or
©
key toggles between reading number, reading, and timestamp.
LIMIT
Use to perform and create limit tests.
AZERO
Use to control auto zero function (on / off).
EXIT
Use to cancel selection and move back to measurement display.
ENTER
Use to accept selection and move to next choice or back to measurement display.
4 Range keys
¹
Use to select the next higher measurement range. Also use to modify the upper auto-
range limit.
ƒ
Use to select the next lower measurement range. Also use to modify the lower auto-
range limit.
AUTO
Enables/disables autorange.
5 Display annunciators
* (asterisk)
Readings being stored in buffer.
(more)
Indicates additional selections are available.
AUTO
Autorange enabled.
BUFFER
Recalling readings stored in buffer.
ERR
Questionable reading or invalid cal step.
FAST
Fast (0.1 PLC) reading rate selected.
FILT
MEDIAN and/or AVERAGE filter enabled.
LSTN
Instrument addressed to listen over GPIB.
MATH
mX+b, m/X+b, or log10 calculation enabled.
MED
Medium (1 PLC) reading rate selected.
REL
Relative enabled for present measurement function.
REM
Instrument in GPIB remote mode.
SLOW
Slow reading rate selected; 6 PLC for 60Hz or 5 PLC for 50Hz.
SRQ
Service request over GPIB.
STAT
Displaying buffer statistics.
TALK
Instrument addressed to talk over GPIB bus.
TIMER
Timer controlled triggering in use.
TRIG
External triggering (GPIB or trigger link) selected.
6 Handle
Pull out and rotate to desired position.
Summary of Contents for 6485
Page 40: ...1 28 Getting Started Model 6485 and 6487 User s Manual...
Page 94: ...7 8 Remote Operation and Commands Model 6485 and 6487 User s Manual...
Page 95: ...A Specifications...
Page 98: ...A 4 Specifications Model 6485 and 6487 User s Manual...
Page 105: ...C ExamplePrograms Programming examples lists and defines three types of programming exam ples...
Page 113: ......
Page 114: ......