Model 2290-5 5 kV Power Supply User's Manual
Section 1: Introduction
2290-5-900-01 Rev. A/December 2013
1-5
POWER
button
Press the
POWER
button so that it is in the on position to turn the
instrument on. Press the
POWER
button so that it is in the off
position to turn it off.
HIGH VOLTAGE
enable switch
This is a three position switch. In the
OFF/RESET
position, the high
voltage is off, and all trips are cleared. In this position, the high
voltage is locked off and cannot be turned on by computer control.
The
ON
position is a momentary-contact position and turns on the
high voltage for manual or rear panel analog control. Note that the
switch should be held in the
ON
position for at least a half second to
turn the high voltage on. In the middle position, the high voltage is
enabled and can be turned on by commands sent over the IEEE-488
bus. The
ON
LED above the switch indicates that the high voltage is
on; the yellow
TRIP
LED indicates a trip has occurred.
VOLTS
LED display Displays the output voltage.
Center LED display
Displays the value of the parameter that is entered or adjusted,
including
Error and status messages
that may occur.
mA
LED display
Displays the output current.
SELECT
,
ENTER
,
CLR
(Clear) button
The
SELECT
button is used to choose which parameter is being
displayed in the center display. The
ENTER
button enters the
parameter shown in the center display. The
CLR
(clear) button
erases the value in the center display and recalls the last value that
was entered.
Numeric and cursor
buttons
All parameters are adjusted using the cursor or numeric buttons.
STATUS
indicators
Three LEDs indicate the instrument's status. The
LIMIT
LED is on
when the unit is in current limit. The
REM
LED is on when the unit is
in remote, and the front panel is locked out. The
FILTER
LED is on
when one of the two available output filters is enabled.
RESET
button
Reset mode determines how the instrument responds after a voltage
or current trip. There are two modes:
MAN
and
AUTO
. In
MAN
(manual) mode the high voltage remains off after a trip and requires
that the operator manually turn it back on.
In
AUTO
(automatic) mode the unit waits until the output voltage has
fallen to 2% of its full-scale value and then turns the high voltage
back on. This feature is useful when dealing with loads that
occasionally short circuit, but recover after high voltage has been
removed.
FILTER
buttons
The output filter, which may be used to reduce output ripple and
noise, is controlled with the
FILTER
,
NO FILTER
,
FILTER 1
, and
FILTER 2
buttons.
GPIB ADDR
buttons The GPIB address buttons set the GPIB primary address.
LOCAL
button
The
LOCAL
button takes the instrument out of remote and restores
operation of other front panel controls.
STO
and
RCL
buttons
STO
(store) and
RCL
(recall) allow up to nine complete instrument
settings to be saved in nonvolatile memory.
RCL
0 recalls the default
settings.