Do not connect switching cards directly to unlimited power circuits. They are intended 
to be used with impedance-limited sources. NEVER connect switching cards directly 
to AC mains. When connecting sources to switching cards, install protective devices to 
limit fault current and voltage to the card. 
Before operating an instrument, ensure that the line cord is connected to a 
properly-grounded power receptacle. Inspect the connecting cables, test leads, and 
jumpers for possible wear, cracks, or breaks before each use. 
When installing equipment where access to the main power cord is restricted, such as 
rack mounting, a separate main input power disconnect device must be provided in 
close proximity to the equipment and within easy reach of the operator. 
For maximum safety, do not touch the product, test cables, or any other instruments 
while power is applied to the circuit under test. ALWAYS remove power from the 
entire test system and discharge any capacitors before: connecting or disconnecting 
cables or jumpers, installing or removing switching cards, or making internal changes, 
such as installing or removing jumpers. 
Do not touch any object that could provide a current path to the common side of the 
circuit under test or power line (earth) ground. Always make measurements with dry 
hands while standing on a dry, insulated surface capable of withstanding the voltage 
being measured. 
For safety, instruments and accessories must be used in accordance with the operating 
instructions. If the instruments or accessories are used in a manner not specified in the 
operating instructions, the protection provided by the equipment may be impaired. 

Do not exceed the maximum signal levels of the instruments and accessories, as 
defined in the specifications and operating information, and as shown on the 
instrument or test fixture panels, or switching card. 
When fuses are used in a product, replace with the same type and rating for continued 
protection against fire hazard. 
Chassis connections must only be used as shield connections for measuring circuits, 
NOT as protective earth (safety ground) connections. 
If you are using a test fixture, keep the lid closed while power is applied to the device 
under test. Safe operation requires the use of a lid interlock. 

 

If a screw is present, connect it to protective earth (safety ground) using the wire 
recommended in the user documentation. 

 

This symbol on an instrument means caution, risk of danger. The user should refer 
to the operating instructions located in the user documentation in all cases where 
the symbol is marked on the instrument. 

 

This symbol on an instrument means caution, risk of electric shock. Use standard 
safety precautions to avoid personal contact with these voltages. 

 

This symbol on an instrument shows that the surface may be hot. Avoid personal 
contact to prevent burns. 

 

This symbol indicates a connection terminal to the equipment frame. 

 

If the mercury symbol is on a product, it indicates that mercury is present in the 
display lamp. Please note that the lamp must be properly disposed of according to 
federal, state, and local laws. 

Summary of Contents for 2280 Series

Page 1: ...Series 2280 Precision Measurement DC Power Supplies Quick Start Guide...

Page 2: ...nly by service personnel Service personnelare trained to workonlive circuits perform safe installations and repairproducts Only properlytrained service personnelmay perform installation and service pr...

Page 3: ...used inaccordance withthe operating instructions If the instruments or accessories are used ina manner not specified inthe operating instructions the protectionprovided by the equipment may be impaire...

Page 4: ...cleananinstrument remove power fromthe instrument Use a damp clothor mild water based cleaner Cleanthe exteriorof the instrument only Do not apply cleaner directly to the instrument or allow liquids t...

Page 5: ...om your measurements In addition you can monitor trends such as drift with the built in plotting functionality As a power supply in an automated test system this power supply provides a list mode and...

Page 6: ...cumentation standard accessories CD ROM and cable housing 4 Remove the packaging insert 5 Remove the Series 2280 from the box Do not lift the Series 2280 from the front bezel Lifting the instrument by...

Page 7: ...de 3 Series 2280 Quick Start Guide this document 4 Series 2280 Precision Measurement DC Power Supplies Product Information CD ROM 5 Model CA 180 3A CAT5 Crossover Cable for Ethernet 6 PA 853D User s G...

Page 8: ...ed signal levels may be constrained by the lowest rated instrument in the system For example if you are using a 500 V power supply with a 300 V DC rated switch the maximum allowed voltage in the syste...

Page 9: ...ou are installing the Series 2280 in a rack To prevent damaging heat build up and ensure specified performance make sure there is adequate ventilation and air flow around the instrument to ensure prop...

Page 10: ...outlet may result in personal injury or death due to electric shock Do not replace detachable mains supply cords with inadequately rated cords Failure to use properly rated cords may result in person...

Page 11: ...heat while carrying the short circuit output current of the unit Please meet the wiring requirements described above Two wire connection The two wire connections are used for basic operation when maxi...

Page 12: ...nd Sense Hi and Output Lo and Sense Lo with the shorting jumpers If you do not do this the display will show incorrect voltage output readings After making the connections slide the cable housing over...

Page 13: ...orting jumpers Before connecting the wire make sure the shorting jumpers have been removed When you connect the power supply for remote sensing the overprotection OVP circuit senses the voltage at the...

Page 14: ...The ENTER key selects a highlighted option In most cases it opens the menu or dialog box that allows you to change settings for that option The EXIT key returns to the previous menu or closes a dialo...

Page 15: ...me screen displays the value of the present outputs and status indicators The outputs show dashed lines until the output is turned on The setting area of the Home screen is located in the lower left c...

Page 16: ...and current measurement using the default instrument configuration Connect the DUT for this example a 1 k resistor to the output binding post on the front panel For details refer to Two wire connecti...

Page 17: ...ure functions What the instrument measures Concurrent V I Measure voltage and current at the same time Voltage V Only measure voltage Current I Only measure current To set the measure function from th...

Page 18: ...alog box is displayed 2 Use the up and down arrow soft keys to select the range The Home page is updated with the new range setting Press ENTER or EXIT to close the Range dialog box To set the ranges...

Page 19: ...rk in the box 4 Highlight Insert and press ENTER to increment the points display until it reads 10 5 Select the Voltage box in the point 1 row Press ENTER 6 Make the value 1 V and press ENTER 7 Select...

Page 20: ...twice to navigate to the 3rd Home screen 7 Press the List soft key The List dialog box is displayed 8 If the Numbersoft key is not showing a 1 press the Number soft key and enter the value 1 9 Press t...

Page 21: ...nformation CD ROM which includes the Series 2280 Reference Manual It provides detailed information about all features of the instrument Also see the Keithley Instruments website www keithley com for s...