background image

C oupling Re placement

 

  FOR KP330

 

Motor Re place ment

 

FOR KP330

 

Removal

 

Installation

 

Removal

 

Installation

 

1.Replace the motor,tighten the 4 screws.

 

1.Push coupling toward input shaft till input shaft

 

  surface,tighten screws  on coupling.

 

1.Relieve pressure,page 5

 

2.Remove screw(1)  and motor cover(2)

 

3.Remove screws(21)(22)

 

4.Remove screws  on one coupling part and

 

    coupling

 

5.Pull out coupling

 

6.Remove screws  on other coupling part of

 

  input shaft

 

7.Pull out coupling

 

2.Push input shaft into motor shaft.Measure the

 

depth 35.5mm-35.7mm with vernier caliper.The

 

measurement  position marked as picture,

 

1.Relieve pressure, page 5.

 

2.Remove coupling,page 12.

 

3.Remove the screws on the control

 

    board case

 

4.Disconnect all motor connnectors from

 

  control board

 

5.Remove the fan (23)

 

6.Remove the screws (24)

 

7.Remove the motor (25)

 

2.Install the coupling.page 12.

 

3.Connect the motor assembly with drive housing,

 

  make  sure two coupling parts are in place.

 

4.Tighten the drive housing with four screws (22).

 

5.Tighten the drive housing with two screws (21).

 

6. Connect motor leads from up to down yellow,

 

      green,blue.

 

7.Tighten control broad cover(27) with screws(26)

 

8.install the motor cover(2).

 

9.Tighten the screw(1)

 

3.Connect the motor assembly with drive housing,

 

    make  sure two coupling parts are in place.

 

4.Tighten four screws(22) with 21 -23 Nm

 

5.Tighten two screws(21) with 21 -23 Nm

 

6.Install back cover

 

7.Tighten three screws(1)

 

21

 

14

 

15

 

Summary of Contents for KP330

Page 1: ...KP330 User Manual Electric AirlessSprayer Important Safety Instructions Read all warnings and instructions in this manual Save theseinstructions...

Page 2: ...the sprayer or for flushing or cleaning keep sprayer at least 20 feet 6 m away from explosive vapors Keep work area free of debris including solvent rags and gasoline Do not plug or unplug power cords...

Page 3: ...g equipment Use only grounded electrical outlets Use only 3 wire extension cords Ensure ground prongs are intact on sprayer and extension cords Do not expose to rain Store indoors PRESSURIZED ALUMINUM...

Page 4: ...e Spray Prime Drain valve in the PRIME DRAIN position unitl you are ready to spray again 2 Engage gun trigger lock if until is being shut down or left unattended Don t change the plug Do not put the m...

Page 5: ...8 Place pump in paint pail Turn power OFF Engage gun trigger lock Increase pressure 1 2 to start motor and allow fluid tocirculate through drain tube for 15 seconds turn pressure down Remove tip guard...

Page 6: ...Trigger gun after moving and release before stopping 3 Increase pressure to 1 2 Hold gun against paint pail Take trigger safety OFF Trigger gun until flushing fluid appears 9 Remove filters from gun...

Page 7: ...ntrol board 4 Use plus driver to loosen the motor connector Connector sequence is yellow green and blue 5 Remove 6 screws from control board 2 Press DTS button once to change to pressure unit PSI Pict...

Page 8: ...five screws 13 Torque to 21 23 N m 2 Install connecting rod 4 and bearing housing 19 to drive housing 3 3 Install four screws 14 Torque to 21 23 N m 4 Install pump 41 Displacement Pump Replacement pa...

Page 9: ...pressure page 5 2 Remove coupling page 12 3 Remove the screws on the control board case 4 Disconnect all motor connnectors from control board 5 Remove the fan 23 6 Remove the screws 24 7 Remove the mo...

Page 10: ...lush pump 2 Relieve pressure page 5 3 Remove screws 28 slid pump rod shield left 29 If pump pin works loose parts could break off due to force of pumping action Parts could project through the air and...

Reviews: