C oupling Re placement
FOR KP330
Motor Re place ment
FOR KP330
Removal
Installation
Removal
Installation
1.Replace the motor,tighten the 4 screws.
1.Push coupling toward input shaft till input shaft
surface,tighten screws on coupling.
1.Relieve pressure,page 5
2.Remove screw(1) and motor cover(2)
3.Remove screws(21)(22)
4.Remove screws on one coupling part and
coupling
5.Pull out coupling
6.Remove screws on other coupling part of
input shaft
7.Pull out coupling
2.Push input shaft into motor shaft.Measure the
depth 35.5mm-35.7mm with vernier caliper.The
measurement position marked as picture,
1.Relieve pressure, page 5.
2.Remove coupling,page 12.
3.Remove the screws on the control
board case
4.Disconnect all motor connnectors from
control board
5.Remove the fan (23)
6.Remove the screws (24)
7.Remove the motor (25)
2.Install the coupling.page 12.
3.Connect the motor assembly with drive housing,
make sure two coupling parts are in place.
4.Tighten the drive housing with four screws (22).
5.Tighten the drive housing with two screws (21).
6. Connect motor leads from up to down yellow,
green,blue.
7.Tighten control broad cover(27) with screws(26)
8.install the motor cover(2).
9.Tighten the screw(1)
3.Connect the motor assembly with drive housing,
make sure two coupling parts are in place.
4.Tighten four screws(22) with 21 -23 Nm
5.Tighten two screws(21) with 21 -23 Nm
6.Install back cover
7.Tighten three screws(1)
21
14
15