Grounding
Metal pail:
Improper installation or alteration of grounding plug
results in risk of electric shock, fire or explosion
that could cause serious injury or death.
Pre ssure Re lief Proce dure
4.Turn pressure to lowest setting. Hold gun
to side of grounded metal flushin g bucket.
Trigger gun to relieve pressure, turn prime
valve down.
Electric:
Grounding Plug
To reduce risk of injury from injection, follow
this procedure whenever you are instructed
to relieve pressure, stop spraying, service
equipment or install or clean spray tip.
Read warnings.
1. Turn power switch OFF and unplug power cord.
waiting at least 7 seconds until the power off.
Attached ground wire to pail and true earth ground.
5.Put drain tube into pail. Leave
Spray-Prime/Drain valve in the PRIME/DRAIN
position unitl you are ready to spray again.
2.Engage gun trigger lock if until is being shut down
or left unattended
Don't change the plug
Do not put the metal pail in a wood or something
nonconductin
Plug power supply cord into a properly grounded
electrical outlet.
Caution:
1.It requires a 220V, 50/60 Hz, 10A- 16A AC
circuit with a grounding receptacle.
2.Confirm without damaged of wire before using.
3.Use a 3-wire, 2.5mm2(12 AWG) (minimum).
Long lengths reduce sprayer performance.
4.Do not alter ground prong or use adapter.
Keep grounding when clean up and pressure relief.
6.If you suspect the spray tip or hose is clogged
3.Remove the tip guard and tip.
or that pressure has not been fully relieved after
following the steps above, VERY SLOWLY loosen
tip guard retaining nut or hose end coupling to
relieve pressure gradually, then loosen completely.
Clear hose or tip obstruction.