Se tup/Installation
Check the intaken of pump for clogs and debris.
Connect KP330 airless hose, to sprayer.
Tighten securely.
Startup
Hold gun against grounded metal flushing pail.
Trigger sure to 1/2. Flush 1minute.
Do the pressure relif. page 5.
Turn pressure control to lowest pressure.
Fill throat packing nut with TSL to p revent premature
packing wear. Do this each time you spray.
Connect other end of hose to gun. Tighten securely.
Turn power on.
Inspect for leaks. Do not stop leaks with hand or
a rag! If leaks occur, do Pressure Relief. Tighten
fittings. Do Startup, 1. - 5. If no leaks, proceed
to 8.
Place pump in paint pail.
Turn power OFF.
Engage gun trigger lock.
Increase pressure 1/2 to start motor
and allow fluid tocirculate through
drain tube for 15 seconds; turn
pressure down.
Remove tip guard.
Plug power supply cord into a properly grounded
electrical outlet.
Turn prime valve down.
Place pump set in grounded metal pail
partially filled with flushing fluid. Attach ground
wire to pail and to true earth ground. Do 1. - 5.
of Startup to flush out storage oil shipped in
sprayer. Use water to flush water-base paint
and mineral spirits to flush oil-base paint and
storage oil.
Set gun safety ON. Assemble tip and guard.
Trigger gun again into flushing pail until
paint appears. Move gun to paint pail and
trigger for 20 seconds.
Turn prime valve horizontal.Take spray
gun trigger safety OFF.