“Lo-bA” will appear on the Power Display to indicate that the batteries are low and need replacement. 
To replace the batteries, refer to Figure 13 and follow the instructions below:

1. 

Open the Performance Trainer by removing the five Phillips Screws along the left side using a #3 Phillips screwdriver.

2. 

Locate the Processor Box at the base. Unscrew the brass nut to remove cover.

3. 

Remove the two D batteries by carefully pulling out the battery sleeve (follow manufacturer’s recommendations for 

handling, maintaining, and disposing of batteries). 

4. 

Observe the correct polarity position (see +/- marking on the circuit board), insert the two new D batteries into the 

battery sleeve and install.

5. 

Replace the Processor Box cover and screw the brass nut finger tight.

6. 

     

IMPORTANT: Avoid pinching the Air Line. 

Route the Air Line along the notch at the base. Close the Performance 

Trainer, align all screw holes and replace the five Phillips Screws using a #3 Phillips Screwdriver.

BATTERY REPLACEMENT

Figure 13. 

Battery Replacement

WARNING:

 Install batteries correctly (+/-). Do not disassemble or dispose of batteries in fire. Check local government 

guidelines for battery disposal/recycling in your area. Battery leakage is extremely caustic and contact with bare 
skin should be avoided. Follow battery manufacturer’s recommendations for care and use.

When the batteries are replaced, the Power Display will run through a test sequence (you will see a series of numbers flashing). 
Once the test sequence stops and the Power Display shows "OFF," the Performance Trainer is ready for use.
NOTE: Upon end of life of your Performance Trainer contact Keiser Customer Support by telephone at 1 559 256 8000, 
online 24/7 at 

keiser.com/support

, or by email at [email protected] for handling directions. Be sure to follow your local 

government guidelines for battery disposal/recycling.

Summary of Contents for INFINITY 3010XP

Page 1: ...PERFORMANCE TRAINER MODEL 3010XP OPERATION MANUAL INFINITY SERIES STRENGTH CARDIO FUNCTIONAL...

Page 2: ...NNUAL SERVICING 16 REGULATORY AND COMPLIANCE NOTICES 16 WARRANTY STATEMENT Keiser the Keiser logo and other trademarks associated with Keiser products referred to in this publication are trademarks of...

Page 3: ...m will be happy to assist by telephone at 1 559 256 8000 online 24 7 at keiser com support or by email at service keiser com Yours in Health Keiser Corporation Register your Performance Trainer to sta...

Page 4: ...rasp of a Cable Accessory during exercise Ensurehookandlooptypeaccessoriesarefastened firmlybeforeexercise CarefullyreturntheCableAccessory to the start position before releasing IMPORTANT SAFETY INFO...

Page 5: ...rdous situation that if not avoided could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related Maintainsafetyandserialnumberlabels Donotremovel...

Page 6: ...operation When Performance Trainers are mountedadjacenttoeachother theTrainingSpace maybeshared ActualCableLengthmayvary based on Accessory type user height and the position of the Vertical Adjustmen...

Page 7: ...ttings Power Display Tube Caps Keiser eChip Accessory Hooks Air Line Mount Tubes Vertical Adjustment Performance Trainer Body Pulley Carriage Cable Link Handle Increase Decrease Thumb Buttons 1 10 5 1...

Page 8: ...TION MANUAL PERFORMANCE TRAINER 08 POWER DISPLAY Figure 5 Power Display Overview When using the eChip ensure that it is fully inserted into the reader as shown 5 8 7 1 3 2 6 4 EXERCISE NUMBER VERTICAL...

Page 9: ...sponding set was a Power Test it displays the resistance to use to achieve maximum power When the calculated resistance to achieve maximum power is being displayed it flashes In summary during an exer...

Page 10: ...ew the nut on the Cable Link 2 Hook the Accessory Ring onto the Cable Link 3 Close the Cable Link by tightening the nut WARNING Avoid serious injury or property damage TheHandleaccessory includedwithy...

Page 11: ...PROPER WARM UP REQUIRED TO HELP PREVENT SERIOUS INJURY This Performance Trainer should only be used with proper instruction Always maintain good form and control during exercise If you feel pain or ar...

Page 12: ...P2 appears in the TARGET REPS window to indicate the start of the second set of the Power Test see Figure 11 4 Increase the resistance to a high level 80 90 of your maximum 5 Do one repetition at maxi...

Page 13: ...ecommended NOTE Your Keiser Air Compressor not included with your Performance Trainer requires basic annual maintenance For complete Keiser Air Compressor maintenance instructions download the user ma...

Page 14: ...Air Line Route the Air Line along the notch at the base Close the Performance Trainer align all screw holes and replace the five Phillips Screws using a 3 Phillips Screwdriver BATTERY REPLACEMENT Figu...

Page 15: ...inder rod clean and coat lightly with clean SAE 30 motor oil or with a silicon based spray 5 Replace Air Filter if element is dirty element turns a bright pink or red color Tools required Small Needle...

Page 16: ...arantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipmen...

Reviews: