background image

RAPT Pill Hydrometer & Thermometer Quick Start Guide 

 

Page 

4

 of 

10 

www.KegLand.com.au

 

Last Updated 1/12/2021 12:53 PM

 

 

2.

 

Once signed up log in to your account on the RAPT portal. 

CONNECT THE RAPT PILL TO YOUR Wifi AND REGISTER THE DEVICE 

Login to your RAPT account and select 

Add New Device

 on the RAPT portal home screen. Then 

select 

RAPT Pill (Digital Hydrometer).

 

Follow the prompts on the RAPT portal to connect your RAPT hydrometer and thermometer to your 
Wi-Fi and register your device to the RAPT Cloud. 

How to connect a RAPT Pill to your Wifi 

Plug your Pill in to a USB charger 

1.

 

From another device, open your Wifi settings and connect to the "RAPT Pill XXX" access 
point using the password "kegland1" 

2.

 

Your device should automatically open a browser to the Pill Captive Portal 

3.

 

Select your Wifi access point, enter your password and select Join 

4.

 

Once you have joined, click on the Registration link to see your MAC address. Write this 
down or copy it on your device. 

How to Register a RAPT Pill to the RAPT Cloud 

1.

 

 

Ensure your RAPT Pill is connected to your Wifi 

2.

 

 From the Pill Captive Portal select the Registration link 

3.

 

 Wait for the User code to appear then click Next 

4.

 

Enter the MAC address and User Code when prompted 

How to Pair your RAPT Pill with another RAPT device 

1.

 

Ensure your RAPT Pill is connected to your Wifi 

2.

 

Click on the Edit Button for your RAPT Pill in the RAPT Portal 

3.

 

Select “Paired Device”

 

4.

 

Choose the RAPT device you wish to pair with 

5.

 

Click Save to finish. 

NOTE: Only ONE RAPT Pill will be displayed on the paired device (such as a RAPT Fermentation 
Chamber). The telemetry for each Pill is viewable in the RAPT Portal separately. 

 

 

Summary of Contents for RAPT KL20596

Page 1: ...RAPT Pill Hydrometer Thermometer Quick Start Guide Page 1 of 10 www KegLand com au Last Updated 1 12 2021 12 53 PM Pill Hydrometer Thermometer KL20596 Quick Start Guide KegLand Distribution PTY LTD...

Page 2: ...ts the battery from completing a connection and draining during shipping Battery Installation If required Only use KegLand approved 18650 rechargeable Lithium ion batteries KL26734 The RAPT Pill Hydro...

Page 3: ...lid Red Charging No Light Fully Charged ESP LED Flashing Green sending or receiving data telemetry SIGN UP FOR A RAPT ACCOUNT To utilise the Wi Fi connectivity of the RAPT Pill Hydrometer you will nee...

Page 4: ...ically open a browser to the Pill Captive Portal 3 Select your Wifi access point enter your password and select Join 4 Once you have joined click on the Registration link to see your MAC address Write...

Page 5: ...using it is important to insert the circuit board in the correct orientation to ensure the correct weight distribution for accurate readings The yellow end of the circuit board should be inserted into...

Page 6: ...STRUCTIONS Your RAPT Pill Hydrometer comes pre calibrated and ready to go after charging assembly and device registration For calibration steps refer to the Calibration section below 1 Submerge your R...

Page 7: ...ng the Calibration process with prevent this from occurring Hence keeping both the Calibration and Diagnostic screens open allows you to easily calibrate the RAPT Pill without losing connection to the...

Page 8: ...t does not matter if the gravity readings are not exactly 10 points apart as long as the gravity reading is correct Use of a hydrometer that is known to be accurate is quite important To perform the r...

Page 9: ...this y 0 0000023109x5 0 0005741632x4 0 0568746764x3 2 8119846525x2 71 1087310405x 265 6578215178 This is a sample only DO NOT USE THIS EQUATION AS IT WILL NOT BE ACCURATE Substitute x in this equatio...

Page 10: ...or support on how to use your RAPT Pill Hydrometer Thermometer or the RAPT Portal If you need hardware support please contact your nearest distributor The RAPT Pill Hydrometer Thermometer comes with a...

Reviews: