background image

NukaTap Counter Pressure Bottle Filler Instruction Manual 

 

Page 

2

 of 

13

 

www.KegLand.com.au

  

  Last Updated 27/07/2021 3:26 PM

 

 

Important 

 

Do not exceed 15psi (100 kPa) 

 

A leak test must be conducted upon initial setup. 

 

Only use KegLand approved cleaning and sanitising chemicals such as StellarClean and 
StellarSan. Do not clean with harsh chlorinated cleaners. 

 

50cm 8mm x 5mm 

EVABarrier Hose 

¼”

 Male x 8mm duotight 

3/8

 Male x 8mm duotight 

for NukaTap Spout 

¼”

 Male x 6.35mm duotight 

Red Gas Male Ball Lock Post 

¼”

 Male x 6.35mm duotight 

Yellow Liquid Male Ball Lock Post 

NukaTap  

Counter Pressure Bottle Filler 

¼”

 Male x Push in Barb 

for NukaTap Spout 

Bored Silicone Bung 

16mm x 19mm 

Summary of Contents for NukaTap KL21760

Page 1: ...essure Bottle Filler Instruction Manual Page 1 of 13 www KegLand com au Last Updated 27 07 2021 3 26 PM NukaTap Counter Pressure Bottle Filler Instruction Manual KL21760 KegLand Distribution PTY LTD w...

Page 2: ...oved cleaning and sanitising chemicals such as StellarClean and StellarSan Do not clean with harsh chlorinated cleaners 50cm 8mm x 5mm EVABarrier Hose Male x 8mm duotight 3 8 Male x 8mm duotight for N...

Page 3: ...OD EVABarrier Hose KL06231 1 x 3 8 Male x 8mm duotight for NukaTap Spout KL18067 1 x Male x 8mm duotight KL06897 1 x Male x Push in Barb for Nukatap Spout 2 x Male x 6 35mm duotight KL08730 1 x Red Ga...

Page 4: ...ou to choose how the bottle filler is configured for your specific use Liquid Beer Inlet Configuration There are multiple ways that Beer Liquid inlet can be configured on your NukaTap counter pressure...

Page 5: ...Male x 8mm duotight fitting into the beer liquid inlet of the NukaTap counter pressure bottle filler 2 Unscrew the spout from the NukaTap on your kegerator 3 Screw the 3 8 Male x 8mm duotight into th...

Page 6: ...also be used to bottle directly from a pressurised FermZilla or keg Connecting to a Keg or Fermzilla with 8mm OD EVABarrier Hose 1 Screw the Male x 8mm duotight fitting into the beer liquid inlet of t...

Page 7: ...Male x 6 35mm duotight fitting into the beer liquid inlet of the NukaTap counter pressure bottle filler 2 Firmly push the barb of the yellow liquid male ball lock post into the duotight fitting on th...

Page 8: ...y into the duotight fitting on the gas inlet Connecting to a regulator via a quick disconnect and EVABarrier Hosing This method allows for your NukaTap Counter Pressure Bottle Filler to be quickly con...

Page 9: ...der off and leave to sit for about 10 15 minutes Then check if the pressure on the regulator has decreased from the set pressure If the pressure has dropped then this indicates that there is a leak in...

Page 10: ...l get in the bottle and hence the faster you will be able to transfer Step 2 Connect your counter pressure bottle filler up to your regulator and your NukaTap Step 3 Sanitise your bottles using a no r...

Page 11: ...the pressure in the keg to reduce foaming Step 8 Open the tap which will allow beer to begin flowing into the bottle If the transfer of liquid into the bottle slows to a halt slowly rotate the large k...

Page 12: ...e procedure for bottling from a FermZilla or keg is the same as bottling from a NukaTap however you want to keep the NukaTap counter pressure bottle filler disconnected from your FermZilla or keg unti...

Page 13: ...cleaner or sanitiser solution to a PET bottle and then pump the solution through the NukaTap counter pressure bottle filler without gas Warranty Australia The Counter Pressure Bottle Filler Kit comes...

Reviews: